Problem
Solution
Motor will not start
SOLUTION: A,B
Low/Surging pressure or no water flow
SOLUTION: C,D,E,F,G,H
No chemical injection
SOLUTION: I,J,K,L
Cause
Solution
A-
Tripped GFCI cord
Reset GFCI cord
B-
Tripped motor relay
Reset motor
C-
Insufficient water supply
See water supply section of this manual
D-
Plugged pump inlet filter
See maintenance section of this manual
E-
Wrong nozzle
Make sure high pressure nozzle is being used
F-
Plugged nozzle
Remove nozzle, check for blockage
G-
Worn nozzle
Replace nozzle
H-
Leak in pressure hose
Replace pressure hose
I-
Wrong nozzle
Make sure chemical nozzle is being used
J-
Back pressure from extra long discharge hose
Try shorter hose
K-
Leak in chemical siphon hose
Replace hose – use hose clamps if necessary
L-
Chemical strainer not submerged
Make sure strainer is completely submerged
The manufacturer reserves the right to make improvements in design
and/or changes in specifications at any time without incurring any
obligation to install them on units previously sold.
Any Questions, Comments, Problems or Parts Orders
Call NorthStar Product Support 1-800-270-0810
Summary of Contents for A1573001
Page 2: ...Hazard Signal Word Definitions 2...
Page 6: ...Pump Component Identification 6 A157306 A1573001 A1573021 A1573011 A1575581...
Page 14: ...Parts Explosion MA1573001 Rev A 1 14...
Page 16: ...Pump Exploded Views 16 A1573001...
Page 17: ...Pump Exploded Views 17...
Page 18: ...Pump Exploded Views 18 A1573011...
Page 19: ...Pump Exploded Views 19 A1573021...
Page 20: ...Pump Exploded Views 20 A157306...
Page 21: ...Pump Exploded Views 21...
Page 22: ...Pump Exploded Views 22 A1575581...
Page 23: ...23 This page has intentionally been left blank...