Step E: Install RO Faucet

INSTALL BATTERY

When the coin battery is first applied at initial start up,

the LED indicator light will flash in red, amber, green

sequence. All timers and counters are reset to zero. In

order to reset the time and gallon count feature, push the

button on the PWA and hold until the LED flashes and

release.The battery needs to be replaced at the time of

filter replacement. Use only lithium batteries (CR 2032 or

equivalent). Improper placement of battery could damage

electronics. Use care when inserting the battery to align it

correctly on the PWA with the proper polarity.

Battery

PWA Board

Reset Button

SELECT LOCATION OF REVERSE OSMOSIS

FAUCET MOUNTING HOLE

You will need to select the location of the Reverse

Osmosis Faucet.  You have three options to choose from:

•  Use the existing sink top hole for the spray hose or

soap dispenser 

(Must be 1-1/4” in diameter)

•  Drill a new hole in the sink 

•  Drill a new hole in the countertop next to the sink

1. Determine where you are going to install your Reverse

Osmosis Faucet. 

2. Check to ensure the Reverse Osmosis faucet will

mount flat against the mounting surface. 

3. Visually review the routing of the tubes from the

Reverse Osmosis filter assembly to the faucet. Check

to ensure there is adequate tube routing space

between the faucet and filter assembly.  

4. If drilling is needed, drill a 1-1/4" diameter hole in the

mounting surface. 

IMPORTANT: Drilling holes into countertops and

sinks should only be performed by an installer who

is qualified for drilling such materials.  Drilling of

surfaces made of stone or solid surface materials

such as granite, marble, Corian™ or other plastic

resin products or sinks made of porcelain or stain-

less steel may cause permanent, irreparable dam-

age to the sink or countertop surface.

FIG. 15

Summary of Contents for NSRO42C4

Page 1: ...ons or concerns when installing operating or maintaining your reverse osmosis system call our toll free number 1 800 972 0135 Monday Friday 7 AM 6 PM CST in Canada please call 1 800 796 6784 or visit...

Page 2: ...ns 4 Unpack and Check Shipment 5 Plan Your Installation 6 7 Overview Site Preparation 8 Installation Instructions 9 19 Step A Install Supply Water Fitting 9 Step B Install Reverse Osmosis Drain 10 11...

Page 3: ...e alteration neglect freezing accident or negli gence and provided further that the Reverse Osmosis Drinking Water System is not damaged as the result of any unusual force of nature such as but not li...

Page 4: ...rsenic Reduction This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine at the system inlet Water systems using an inline chlor...

Page 5: ...ged in shipment Note any damage to the shipping carton Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or damaged items If problems exist...

Page 6: ...tank may be installed in a kitchen or bathroom sink cabinet See Fig 4 A suitable drain point is needed for drain water from the Reverse Osmosis system REMOTE INTERIOR LOCATION The Reverse Osmosis Filt...

Page 7: ...Cold Water Supply Storage Tank Sink Drain P Trap Shutoff Valve Reverse Osmosis Assembly HOT COLD Tee Feed Adaptor Outside Faucet Hard Water Soft Cold Water Soft Hot Water Outside Faucet Hard Water Wat...

Page 8: ...efore starting close the hot and cold water shutoff valves See Figure 7 2 Temporarily place tank and filter assembly into planned location Check position of items and space required for proper install...

Page 9: ...alves If you live in the state of Massachusetts review plumb ing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installation INSTALL COLD WATER SUPPLY FITTING Included wi...

Page 10: ...r 1 Slowly disassemble the sink drain pipe between the sink P trap and the sink tailpiece See Fig 8 10 2 Clean the sink tailpiece to assure a leak tight fit 3 Install drain adapter directly onto the s...

Page 11: ...back of manual may be needed 3 If longer tubing is required disconnect the 1 4 red tubing and replace with an adequate length of tubing to reach the drain point Refer to Step F later in the manual on...

Page 12: ...g steps to install your Reverse Osmosis Filter Assembly 1 Remove the cover 2 Locate mounting slots on back inside of the assem bly See Fig 13 3 Hold the assembly up to the wall surface and mark locati...

Page 13: ...nipple at the top of the tank See Fig 14 2 Locate the tubing connector See Fig 14 Tighten the tubing connector onto the tank nipple 7 8 full turns being careful not to cross thread or overtighten 3 D...

Page 14: ...e the existing sink top hole for the spray hose or soap dispenser Must be 1 1 4 in diameter Drill a new hole in the sink Drill a new hole in the countertop next to the sink 1 Determine where you are g...

Page 15: ...regard step 5 and move on to step 6 5 Route the 1 4 red tubing from the bottom up through the faucet mounting hole Push the end of the tubing onto the 1 4 barb fitting See Fig 17 NOTE Tubing lengths s...

Page 16: ...collet until it engages the o ring See Fig 20 Continue pushing until the tube bottoms out against the back of the fitting See Fig 21 Do not stop pushing when the tube engages the o ring Failure to fol...

Page 17: ...4 Insert all the way into the fitting See Figs 20 21 5 Pull on the tube to be sure it s held firmly in the fitting CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1 Locate the 3 8 bla...

Page 18: ...the Reverse Osmosis system is off 2 Open the Reverse Osmosis faucet If the tank is not already empty allow the water to empty 3 Locate the eyedropper included in parts bag and common household bleach...

Page 19: ...system is producing water even if you are not drawing water from the Reverse Osmosis faucet You may hear a small quantity of water going to the drain at times when water is not being used This is norm...

Page 20: ...has a hand operated knob to dispense drinking water See Fig 28 An air gap is built into the faucet drain water connection to comply with plumbing codes See Fig 28 FAUCET ELECTRONICS The RO system wil...

Page 21: ...to the storage tank 5 Drain water with dissolved solids leaves the Reverse Osmosis membrane and flows to the drain 6 Faucet is activated 7 Processed water leaves the storage tank and flows to the post...

Page 22: ...he following steps to replace the cartridges NOTE Do not remove manifold from mounts Flexing or twisting may damage the manifold 1 Remove turn to the left the prefilter cartridge from the manifold to...

Page 23: ...in the manifold when the push in elbow fitting is removed you will need to remove the drain port s collet and o ring as shown in the next sec tion to retrieve it CHANGE COLLET AND O RING 1 Remove the...

Page 24: ...lter cartridge and Reverse Osmosis membrane cartridge See Page 22 Problem System makes lower amount of product water than usual Cause Storage tank air charge less than 5 7 psi Correction Open Reverse...

Page 25: ...bing square See pages 16 17 Cause Tubing not pushed in all the way Correction Push tubing in all the way See pages 16 17 Cause Tubing nicked Correction Remove tube from connection Remove nicked portio...

Page 26: ...26 Exploded View 28 27 26 24 23 22 21 20 1 4 red tubing 18 13 10 9 7 6 4 5 3 1 2 25 11 16 17 15 19 8 14 12 6...

Page 27: ...11 Screw 2 req d 12 Cover Paddlewheel 13 Paddlewheel 14 O Ring Paddlewheel Key No Part No Description 15 7296521 Rep l Manifold Assembly includes Key Nos 1 8 11 14 7333129 Mounting Hardware Kit inclu...