background image

3. PART 2 - For Users

3.0 PUT IN OPERATION - GENERAL PRECAUTIONS ...................................

We  would  like  to  remind  you  that  these  appliances  are  designed  exclusively
professional use and must be operated by specialized personnel.
In  order  to  set  the  crepe  machine  into  operation,  observe  meticulously
everything include these pages as well as ordinary safety measures:

  Verify that there are not escapes of gas.

  Verify  the  stability  of  the  flames  passing  from  the  maximum  to  the

minimum setting.

  Check the regular lighting of the main burner.

  Verify that there is a good influx of fresh air.

Look out for not surfaces on the outside of the appliance
during preparation and grilling. These are clearly marked
with the symbol shown on the right.
After making sure the appliance has been correct
connected to the electricity and gas supplies you can
ignite and start using it.

NORTH APPLIANCES DOES NOT EQUIPPED WITH A
PIEZOELLECTRIC IGNITER IF YOU WANT TO IGNITE
BURNERS YOU NEED TO USE A MATCH OR A LIGHTER

3.0 LIGHTING BURNER – TURN THE MOTOR ON AND LAMP.....................

  When appliance is off, the gate valve is vertical and the round indication I

top.

  Push  the  knob  slightly  and  turn  it  anti-clockwise  until  you  bring  it  to  the

flame indication.

  While you keep the handle pressed, light the appliance using a candle.

  Keep the handle pressed for a few seconds until the thermocouple.

  Turn  the  handle  anti-clockwise  until  you  bring  it  to  the  position  of  the

highest flame and make sure the burner is turned on completely.

  The following nick is that of the medium flame; you can choose this setting

once machine has reached the desired temperature.

  Make the same step to turn on the other entire burner.

  To  turn  on  the  motor  in  the  right  side of  the  machine  are  the  RED  switch

on/off the one which are in the bottom are for the lamp inside the machine
the other are for the motor.

Summary of Contents for GAS5

Page 1: ...K9 These appliances comply with requirements of E E C 90 396 SOTIRIOS D PRODANAS CO PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANT PATISSERIES SNACK BAR OFFICE FACTORY National Road Kilkis Thessaloniki Tel 30 23410 41819 Fax 30 23410 41539 P O Box 400 70 P C 560 00 www north gr e mail info north gr ...

Page 2: ...mended for or not foreseen in this manual FIGURE 1 Technical Characteristics MODEL DIMENSIONS mm DESCRIPTION TYPE OF BURNER GAS K2 1320 x 410 x 685 1 burners Ceramic GAS K3 1320 x 410 x 855 2 burners Ceramic GASK5 1320 x 410 x 1260 4 burners Ceramic GASK9 1320 x 590 x 1260 4 burners Ceramic FIGURE 2 Technical Data Technical Data Unit GAS 2 GAS 3 GAS K5 GASK9 Normal thermal energy provide Kw 6 20 1...

Page 3: ...ke sure packing is intact before remove the appliance Open cardboard carefully to ensure no metal stapling adhesive tape or other packing components litter the environment as these can prove hazardous 1 0 OBSTACLES AND POSITION Make sure there is enough space available to place the appliance and that the surface it stands on is stable and level Remove the protective film from the external walls of...

Page 4: ...tion of the appliance are to be found on the label on the backside of the appliance Connect the machine to the network using metal pipes either rigid or flexible Verify that the pressure in use is that of exercise for which the appliance has been predisposed In no case the pressure must exceed 50 mbars Use the right sealing materials for all connections and check them for leaks It is important for...

Page 5: ...appliances must always be installed below 200 mm on three sides an aspirant which directs fume outdoors The appliances whose total thermal power is superior to 14Kw must be obligatorily installed under aspirant intercepting and piloting the system of feeding of the gas of the appliance Particularly the supply circuit electric valve at the top of the appliance must be switched off Make sure that th...

Page 6: ...sing of the taking of pressure Connect the manometer and to measure the pressure Remove the manometer re screw the screw and verify that there are not leaks 2 0 REGULATION FOR THE OPERATION WITH DIFFERENT GAS Both the packing and on the appliance carry the regulation data for suitable gases If regulation is necessary for other type gas you should Verify that type of gas and pressure corresponds to...

Page 7: ...ability of the flame of the main burden Check that non combusted gases have an appropriate outlet 2 0 INTERVENTIONS REPAIRS AND REPLACEMENT only for the authorized technicians Even if the appliance is used correctly some problems may arise for various reasons The table that follows mentions some possible problems and some suggestions to put them right CAUTION Before performing any intervention of ...

Page 8: ... 0 SAFETY VALVE The valve that regulates the influx of the gas is provided safety thermal that it assures the block of influx of the gas in case of accidental turning off of the flame 2 0 REGULATION OF THE MINIMUM BURNING The nozzle of the valve bypass has a hole of 0 50 mm and for the gas G30 Must be fully screwed In case of regulation for other gases G20 the bypass must be unscrewed by Turning t...

Page 9: ...substitution of the valve it is necessary to unscrew the connections in the following order First the connection of the thermocouple then the connection of the gas outlet exit gas and finally the connection of entrance gas Replacing other parts such as the thermocouple candle of lighting is simple and intuitive after having removed the base wall ...

Page 10: ...an ignite and start using it NORTH APPLIANCES DOES NOT EQUIPPED WITH A PIEZOELLECTRIC IGNITER IF YOU WANT TO IGNITE BURNERS YOU NEED TO USE A MATCH OR A LIGHTER 3 0 LIGHTING BURNER TURN THE MOTOR ON AND LAMP When appliance is off the gate valve is vertical and the round indication I top Push the knob slightly and turn it anti clockwise until you bring it to the flame indication While you keep the ...

Page 11: ...intenance is necessary to close the gas supply found at the top of the appliance It is consulted to the user to undersign to contract of maintenance with technical personnel that foresees at least one full check up annually We specifically recommend regular checking to make sure the flame regulation are clean The gate valve and thermocouple must be checked at least once a year and if necessary res...

Reviews: