background image

3.2A   PREPARING THE SPIT .......................................................

  Take off the spit from the machine by push the needle side of the spit

inside the hole (needle side on the left of the spit)

  Place the meat on the spit with the herbs and spices you have

already prepared, and use the hook to be press it.

  Put the spit with the meat in the machine.

  Secure the spit to be correct in his position by putting the square side

for good.

Now the appliance is ready to operate. All you have to do is set the desired
flame and start the rotation motor by pressing the switch.

3.0 MAINTENANCE...........................................................................................

  Before  performing  any  job  of  maintenance  is  necessary  to  close  the  gas

supply found at the top of the appliance.

  It  is  consulted  to  the  user  to  undersign  to  contract  of  maintenance  with

technical personnel that foresees at least one full check-up annually.

  We  specifically  recommend  regular  checking  to  make  sure  the  flame

regulation are clean.

  The  gate  valve  and  thermocouple  must  be  checked  at  least  once  a  year

and, if necessary, restored the protection of specific oil.

  An  accurate  observance  of  the  contained  instructions  in  this  manual  are

observed, NORTH appliances will allow perfect use for a long time.

The manufacturer cannot be held responsible for any damage caused to
property, human beings or animals due to misuse of the appliances or non-
observance of instructions included in this manual.

Summary of Contents for GAS5

Page 1: ...K9 These appliances comply with requirements of E E C 90 396 SOTIRIOS D PRODANAS CO PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANT PATISSERIES SNACK BAR OFFICE FACTORY National Road Kilkis Thessaloniki Tel 30 23410 41819 Fax 30 23410 41539 P O Box 400 70 P C 560 00 www north gr e mail info north gr ...

Page 2: ...mended for or not foreseen in this manual FIGURE 1 Technical Characteristics MODEL DIMENSIONS mm DESCRIPTION TYPE OF BURNER GAS K2 1320 x 410 x 685 1 burners Ceramic GAS K3 1320 x 410 x 855 2 burners Ceramic GASK5 1320 x 410 x 1260 4 burners Ceramic GASK9 1320 x 590 x 1260 4 burners Ceramic FIGURE 2 Technical Data Technical Data Unit GAS 2 GAS 3 GAS K5 GASK9 Normal thermal energy provide Kw 6 20 1...

Page 3: ...ke sure packing is intact before remove the appliance Open cardboard carefully to ensure no metal stapling adhesive tape or other packing components litter the environment as these can prove hazardous 1 0 OBSTACLES AND POSITION Make sure there is enough space available to place the appliance and that the surface it stands on is stable and level Remove the protective film from the external walls of...

Page 4: ...tion of the appliance are to be found on the label on the backside of the appliance Connect the machine to the network using metal pipes either rigid or flexible Verify that the pressure in use is that of exercise for which the appliance has been predisposed In no case the pressure must exceed 50 mbars Use the right sealing materials for all connections and check them for leaks It is important for...

Page 5: ...appliances must always be installed below 200 mm on three sides an aspirant which directs fume outdoors The appliances whose total thermal power is superior to 14Kw must be obligatorily installed under aspirant intercepting and piloting the system of feeding of the gas of the appliance Particularly the supply circuit electric valve at the top of the appliance must be switched off Make sure that th...

Page 6: ...sing of the taking of pressure Connect the manometer and to measure the pressure Remove the manometer re screw the screw and verify that there are not leaks 2 0 REGULATION FOR THE OPERATION WITH DIFFERENT GAS Both the packing and on the appliance carry the regulation data for suitable gases If regulation is necessary for other type gas you should Verify that type of gas and pressure corresponds to...

Page 7: ...ability of the flame of the main burden Check that non combusted gases have an appropriate outlet 2 0 INTERVENTIONS REPAIRS AND REPLACEMENT only for the authorized technicians Even if the appliance is used correctly some problems may arise for various reasons The table that follows mentions some possible problems and some suggestions to put them right CAUTION Before performing any intervention of ...

Page 8: ... 0 SAFETY VALVE The valve that regulates the influx of the gas is provided safety thermal that it assures the block of influx of the gas in case of accidental turning off of the flame 2 0 REGULATION OF THE MINIMUM BURNING The nozzle of the valve bypass has a hole of 0 50 mm and for the gas G30 Must be fully screwed In case of regulation for other gases G20 the bypass must be unscrewed by Turning t...

Page 9: ...substitution of the valve it is necessary to unscrew the connections in the following order First the connection of the thermocouple then the connection of the gas outlet exit gas and finally the connection of entrance gas Replacing other parts such as the thermocouple candle of lighting is simple and intuitive after having removed the base wall ...

Page 10: ...an ignite and start using it NORTH APPLIANCES DOES NOT EQUIPPED WITH A PIEZOELLECTRIC IGNITER IF YOU WANT TO IGNITE BURNERS YOU NEED TO USE A MATCH OR A LIGHTER 3 0 LIGHTING BURNER TURN THE MOTOR ON AND LAMP When appliance is off the gate valve is vertical and the round indication I top Push the knob slightly and turn it anti clockwise until you bring it to the flame indication While you keep the ...

Page 11: ...intenance is necessary to close the gas supply found at the top of the appliance It is consulted to the user to undersign to contract of maintenance with technical personnel that foresees at least one full check up annually We specifically recommend regular checking to make sure the flame regulation are clean The gate valve and thermocouple must be checked at least once a year and if necessary res...

Reviews: