0. PART I - Installation

We will present essential data, the technical characteristics and our advice for
to correct installation use and maintenance of the appliances described.
Let us remind you that the appliances are for professional use and that all the
procedures of installing, connecting to the distribution network and positioning
of  the  appliance  in  operation  should  be  carried  out  by  properly  qualified
personnel and that all safety measures applicable in the country of installation
should be observed.

The manufacturer cannot be held responsible for any possible damages
caused  to  property,  human  beings  or  animal  that  might  be  caused  by
misuse  of  the  appliance  or  by  using  the  appliance  for  purposes  other
than those recommended for or not foreseen in this manual.

FIGURE 1 - Technical Characteristics

MODEL

DIMENSIONS mm

DESCRIPTION

TYPE OF BURNER

GAS K2

1320 x 410 x 685

1 burners

Ceramic

GAS K3

1320 x 410 x 855

2 burners

Ceramic

GASK5

1320 x 410 x 1260

4 burners

Ceramic

GASK9

1320 x 590 x 1260

4 burners

Ceramic

FIGURE 2 - Technical Data

Technical Data

Unit

GAS  2

GAS  3

GAS K5

GASK9

Normal 

thermal

energy provide

Kw

6,20

12,40

24,8

24,8

Consumption G30

Kg/h

0,48

0,98

1,96

1,96

Consumption G20

m³/h

0,66

1,31

2,62

2,62

Main  air  regulation  at
G30 28... 30mbar G31
37mbar

mm

8

2X8

4X8

4X8

Main  air  regulation  at
G20 20mbar

mm

10

2X10

4X10

4X10

Main  burner  injector
G30 28... 30mbar G31
37mbar

mm

1,15

2X1,15 

4X1,15 

4X1,15

Main  burner  injector
G20 20mbar

mm

1,85

2X1,85 

4X1,85 

4X1,85

By-pass G30

(28...30mbar 

 G31

37mbar)

mm

1,20

2X1,20 

4X1,20 

4X1,20

By-pass G20  20mbar

mm

Reg.

2XReg.

Reg.

Reg.

Kcal

5334

10669

21338

21338

Mj

22,32

44,64

89,28

89,28

CALORIES

BTU

21158,8 

42317,5 

84635

84635

Summary of Contents for GAS5

Page 1: ...K9 These appliances comply with requirements of E E C 90 396 SOTIRIOS D PRODANAS CO PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANT PATISSERIES SNACK BAR OFFICE FACTORY National Road Kilkis Thessaloniki Tel 30 23410 41819 Fax 30 23410 41539 P O Box 400 70 P C 560 00 www north gr e mail info north gr ...

Page 2: ...mended for or not foreseen in this manual FIGURE 1 Technical Characteristics MODEL DIMENSIONS mm DESCRIPTION TYPE OF BURNER GAS K2 1320 x 410 x 685 1 burners Ceramic GAS K3 1320 x 410 x 855 2 burners Ceramic GASK5 1320 x 410 x 1260 4 burners Ceramic GASK9 1320 x 590 x 1260 4 burners Ceramic FIGURE 2 Technical Data Technical Data Unit GAS 2 GAS 3 GAS K5 GASK9 Normal thermal energy provide Kw 6 20 1...

Page 3: ...ke sure packing is intact before remove the appliance Open cardboard carefully to ensure no metal stapling adhesive tape or other packing components litter the environment as these can prove hazardous 1 0 OBSTACLES AND POSITION Make sure there is enough space available to place the appliance and that the surface it stands on is stable and level Remove the protective film from the external walls of...

Page 4: ...tion of the appliance are to be found on the label on the backside of the appliance Connect the machine to the network using metal pipes either rigid or flexible Verify that the pressure in use is that of exercise for which the appliance has been predisposed In no case the pressure must exceed 50 mbars Use the right sealing materials for all connections and check them for leaks It is important for...

Page 5: ...appliances must always be installed below 200 mm on three sides an aspirant which directs fume outdoors The appliances whose total thermal power is superior to 14Kw must be obligatorily installed under aspirant intercepting and piloting the system of feeding of the gas of the appliance Particularly the supply circuit electric valve at the top of the appliance must be switched off Make sure that th...

Page 6: ...sing of the taking of pressure Connect the manometer and to measure the pressure Remove the manometer re screw the screw and verify that there are not leaks 2 0 REGULATION FOR THE OPERATION WITH DIFFERENT GAS Both the packing and on the appliance carry the regulation data for suitable gases If regulation is necessary for other type gas you should Verify that type of gas and pressure corresponds to...

Page 7: ...ability of the flame of the main burden Check that non combusted gases have an appropriate outlet 2 0 INTERVENTIONS REPAIRS AND REPLACEMENT only for the authorized technicians Even if the appliance is used correctly some problems may arise for various reasons The table that follows mentions some possible problems and some suggestions to put them right CAUTION Before performing any intervention of ...

Page 8: ... 0 SAFETY VALVE The valve that regulates the influx of the gas is provided safety thermal that it assures the block of influx of the gas in case of accidental turning off of the flame 2 0 REGULATION OF THE MINIMUM BURNING The nozzle of the valve bypass has a hole of 0 50 mm and for the gas G30 Must be fully screwed In case of regulation for other gases G20 the bypass must be unscrewed by Turning t...

Page 9: ...substitution of the valve it is necessary to unscrew the connections in the following order First the connection of the thermocouple then the connection of the gas outlet exit gas and finally the connection of entrance gas Replacing other parts such as the thermocouple candle of lighting is simple and intuitive after having removed the base wall ...

Page 10: ...an ignite and start using it NORTH APPLIANCES DOES NOT EQUIPPED WITH A PIEZOELLECTRIC IGNITER IF YOU WANT TO IGNITE BURNERS YOU NEED TO USE A MATCH OR A LIGHTER 3 0 LIGHTING BURNER TURN THE MOTOR ON AND LAMP When appliance is off the gate valve is vertical and the round indication I top Push the knob slightly and turn it anti clockwise until you bring it to the flame indication While you keep the ...

Page 11: ...intenance is necessary to close the gas supply found at the top of the appliance It is consulted to the user to undersign to contract of maintenance with technical personnel that foresees at least one full check up annually We specifically recommend regular checking to make sure the flame regulation are clean The gate valve and thermocouple must be checked at least once a year and if necessary res...