Page 22 of 220 Installing the hardware
553-3601-200 Standard 7.00 November 1998
Figure 9 : RPI components
There are two versions of the RPI unit: the RPI-8 BIX UL, which supports up
to eight Base Stations; and the RPI-16 BIX UL, which supports up to 16 Base
Stations. Each RPI has a connection board and either one (RPI-8 BIX UL) or
two (RPI-16 BIX UL) power supply units. The maximum input power
consumption of an RPI is 240 W. If a UPS 48 V dc backup source is used, the
maximum input power requirement of the RPI is 140 W.
You can upgrade an RPI-8 BIX UL to an RPI-16 BIX UL by attaching a
second power supply unit to the RPI-8 as described on page 32.
To determine the type and number of power supply units you need for a given
number of Base Stations, use Table 2 on page 23.
WARNING!
An RPI unit should not be installed where its
outputs are exposed, even when the Base
Station is installed with the TCM lines
exposed. An RPI unit should be installed in
the same building as the Base Stations the
RPI supports.
PSU 1
PSU 2
(if equipped)
Up to 16 outputs
(TCM + power)
Up to
16
inputs
(TCM)
connection board
jumper cable to PSU 2
power cord
grounding strap
power supply cabling
strain relief support
clip
grounding plates
ferrite rings
dc supply
Summary of Contents for Meridian 1 PC Console Interface Unit
Page 2: ......
Page 10: ...Page x of x 553 3601 200 Standard 7 00 November 1998 ...
Page 78: ...Page 68 of 220 Installing the hardware 553 3601 200 Standard 7 00 November 1998 ...
Page 82: ...Page 72 of 220 System initialization 553 3601 200 Standard 7 00 November 1998 ...
Page 108: ...Page 98 of 220 Activating wireless communications 553 3601 200 Standard 7 00 November 1998 ...
Page 128: ...Page 118 of 220 Programming user options 553 3601 200 Standard 7 00 November 1998 ...
Page 204: ...Page 194 of 220 Troubleshooting 553 3601 200 Standard 7 00 November 1998 ...
Page 230: ...Page 220 of 220 Index 553 3601 200 Standard 7 00 November 1998 ...
Page 231: ......