1-4 NT5K17 Direct Dialing Inward Trunk Card
553-3001-173 UK Trunk cards description
Technical description
The technical details of the NT5K17 Direct Dialling Inward trunk card are
outlined below.
Power requirements
Table 1-1 lists the power requirements for the NT5K17 DDI trunk card.
Table 1-1
NT5K17 power requirements
Vo lt age
I dle cu rr ent
Ac ti ve cur ren t
+ 15. 0 V dc
195 ma
195 ma
- 15 V dc
240 ma
215 ma
+8. 5 V dc
85 ma
85 ma
- 48 V dc
50 ma
500 ma
+ 5.0 V dc
195 ma
175 ma
Environmental specifications
Table 1-2 lists the environmental specifications for the NT5K17 DDI card.
Table 1-2
NT5K17 Environmental specifications
Par amet er
Sp ecif i cat io ns
Oper at i ng
t emper at ur e
0 to 50 degr ees C , ambi ent
Oper at i ng hum i di ty
5 to 95 % RH ( non- c ondensi ng)
St or age t emper at ur e
- 50 t o + 70 degr ees C
PAD switching
Loss values for the NT5K17 DDI trunk card are as follows:
Lo ss
An alo g- t o - Di gi t al
Di gi t al- t o - An alo g
PAD out
- 4 d B
- 3 d B