North
Q
Power & Gas Reader
Revision: 2.2
8
For Gas Readers (gas):
Only applies to gas readers with firmware version 3.30 or higher configured for SILVER SPOT!
Setting the value 0 on this register will restart the calibration process will restart the calibration
process that occurs normally at power-up. The calibration process lasts aprox. 2 minutes.
Interrogating this register will return the current calibration percentage, from 0 to 100, value
100 indicating that the calibration has ended.
9. COMMAND_CLASS_MANUFACTURER_SPECIFIC
The Power Reader will respond to a MANUFACTURER SPECIFIC GET command with the
following information:
- MANUFACTURER SPECIFIC for electricity firmware:
Manufacturer:
150
Product:
1
Product type:
1
- MANUFACTURER SPECIFIC for gas firmware:
Manufacturer:
150
Product:
1
Product type:
16
10. COMMAND_CLASS_VERSION
This command class is implemented according to the command class specification.
11. COMMAND_CLASS_METER_TBL_MONITOR
The meter tbl monitor command class is implemented according to the command class
specification.
NOTE:
The Power Reader will not report any data through this command class if the time
parameters are not set.
IV. Power Reader push button commands
The Power Reader can take commands by pressing the button. The following commands
are supported:
- By pressing the button 1 time the Power Reader will enter real-time mode. The proper
configuration reports will be sent to notify the controlling node.
- By pressing the button 2 times the Power Reader to wake up from sleep and send a wake up
notification.