Radar/Chart Radar User Guide
Targets
65900010 10-13
The CPA/TCPA and BCR/BCT values for a target are shown on the Target
Data tab folder of the Selected Target sub menu.
Target Monitoring Symbols
The system shows the following alarm monitoring symbols used for targets.
CPA/TCPA and BCR
infringements see Limits
and Settings
Solid circle
Unacknowledged alert - flashing red
Acknowledged alert - solid red
Acquisition Zone
infringement - acquiring
Dashed circle.- target manually selected
in Zone
Flashing red until Acquisition Zone
infringement is established.
Acquisition Zone
infringement -established
Small solid circle
Unacknowledged alert – flashing red
AZ zone infringement -
established and
acknowledged
Small solid dot
Acknowledged alert – solid green
Lost Target
Crossed flashing red lines centred on
the current target symbol.
Only one
alert
symbol appears on a target at any one time. The order of
precedence is:
1. CPA/TCPA/
BCR
2. Lost
Target
3. Acquisition Zone infringement
Although the audible
alert
may be temporarily or permanently muted
(dependent on commissioning) the visual alert symbol will always apply,
unless tracking has ceased, or the
alert
condition no longer applies.
Summary of Contents for VisionMaster FT
Page 1: ...Radar Chart Radar User Guide Northrop Grumman Sperry Marine B V Part Number 65900010 ...
Page 2: ......
Page 4: ...Radar Chart Radar User Guide 65900010 ii Intentionally Blank ...
Page 24: ...Overview Radar Chart Radar User Guide 1 2 65900010 Single System ...
Page 42: ......
Page 114: ......
Page 212: ......
Page 304: ......
Page 370: ......
Page 450: ......
Page 462: ......
Page 502: ......
Page 516: ......
Page 532: ......
Page 533: ......