System
Radar/Chart Radar User Guide
14-30
65900010
Unauthorized System
If the system is not authorized the tab folder
states that the system is unauthorized and will
revert to a degraded state of functionality,
counting down from 7 days after the
authorization initially failed.
When the system is in a degraded state,
the display becomes unstabilised (Head
Up mode). In this mode there is no
target tracking or chart data available.
A temporary password can be supplied by your
VisionMaster supplier on request. The password
will contain:
System
PIN
Product type identifier
Expiration date (typically 30 days from the
time it is requested).
Enter the password in the
Temporary
Authorisation Password
field and click the
Submit
button. The system verifies the
password and, if correct, the node is temporarily
authorized and a PIN is displayed.
When a password has been entered and its expiry date has not yet been
reached, the system will run as fully authorized.
When the node is running on a temporary password, a warning is given,
repeated once per day, indicating when the password will expire. After the
password expiry date has been reached, the node reverts to an
unauthorized state.
If a security block authorization fails on any node, and this is not remedied
by entry of a password the system will do the following:
produce a warning every 15 minutes.
run normally on that node until 7 days (calendar time) have passed
since the authorization initially failed.
operate in a state of degraded functionality after the 7-day period
expires.
Summary of Contents for VisionMaster FT
Page 1: ...Radar Chart Radar User Guide Northrop Grumman Sperry Marine B V Part Number 65900010 ...
Page 2: ......
Page 4: ...Radar Chart Radar User Guide 65900010 ii Intentionally Blank ...
Page 24: ...Overview Radar Chart Radar User Guide 1 2 65900010 Single System ...
Page 42: ......
Page 114: ......
Page 212: ......
Page 304: ......
Page 370: ......
Page 450: ......
Page 462: ......
Page 502: ......
Page 516: ......
Page 532: ......
Page 533: ......