Problem
Possible Causes
Possible Remedies
Engine will not
start.
a) Low oil level.
b) Fouled spark plug.
c) Out of fuel.
d) Stop switch in OFF position.
a) Fill crankcase to proper oil level.
b) Clean or replace spark plug.
c) Fill fuel tank.
d) Place switch in ON position.
Voltage too low.
a) Engine speed too slow.
b) Generator is overloaded.
a) Bring generator to a qualified technician
for adjustment.
b) Reduce the load. (See Power Load
Planning & Mgt. section of this manual.)
Circuit breaker
trips.
a) Defective load connected to
generator.
b) Defective receptacle.
c) Generator overloaded.
a) Disconnect load.
b) Replace receptacle.
c) Reduce the load. (See Power Load
Planning & Mgt. section of this manual.)
Voltage too high.
a) Engine speed too high.
a) Bring generator to a qualified technician
for adjustment.
Generator
overheating.
a) Generator is overloaded.
b) Insufficient ventilation.
a) Reduce the load. (See Power Load
Planning & Mgt. section of this manual.)
b) Make sure there is at least 7 feet of
clearance on all sides of generator.
No output
voltage.
a) Defective load connected to
generator.
b) Broken or loose wire.
c) Defective receptacle.
d) Defective stator.
e)
Defective rotor.
f)
Defective capacitor.
g) Circuit breaker tripped.
a)
Disconnect load.
b) Bring generator to a qualified technician
for repair.
c) Replace receptacle.
d) Bring generator to a qualified technician
for repair.
e) Bring generator to a qualified technician
for repair.
f)
Bring generator to a qualified technician
for repair.
g)
Reset circuit breaker and reduce loads
connected to the generator.
Engine lacks
power.
a) Generator is overloaded.
b) Dirty air filter.
a) Reduce the load. (See Power Load
Planning & Mgt. section of this manual.)
b) Clean or replace air filter.
Engine shuts
down during
operation.
a) Out of fuel.
b) Low oil level.
a) Fill fuel tank.
b) Fill crankcase to proper oil level.
Summary of Contents for 165601
Page 2: ...Hazard Signal Word Definitions 2 ...
Page 43: ...Generator Exploded View Rev O 3 Item s 165601 165603 165604 43 ...
Page 45: ...Generator Exploded View Rev O 3 Item s 165605 165606 165607 45 ...
Page 47: ...Control Panel Parts List Rev O 3 47 Item 165601 Item 165603 Item 165604 ...
Page 48: ...Control Panel Parts List Rev O 3 48 Item 165605 Item 165606 Item 165607 ...
Page 50: ...Generator Head Exploded Views Rev O 3 Item s 165601 165603 165604 165605 50 ...
Page 52: ...Generator Head Exploded Views Rev O 3 Item s 165606 165607 52 ...
Page 54: ...54 This page has intentionally been left blank ...
Page 56: ...56 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com ...