Page 13 of 35
1. Check the hydraulic fluid level before the engine is started and after every 25 hours of operation.
The fluid type is H68 or equivalent. The hydraulic tank capacity is 33 liters.
2. Position machine on level surface. Lower the loader arms and stop the engine.
3. Clean the area around filler neck of the hydraulic tank.
4. Remove the cap from the filler neck and check the fluid level. The fluid level should be
approximately 75-100mm below the top of the tank.
5. If the level is low, add fluid.
6. Return cap to the filler neck.
Pre-Start Inspection
It is very important to do a visual inspection of the machine before beginning operation. This
inspection should include:
•
Check all decals and warning signs for damage.
•
Check all fuel, oil and hydraulic lines, hoses fittings and connections for signs of damage or
leaks.
•
Inspect the machine for any signs of damage or loose fasteners.
•
Check for any signs of
leaking fluids.
•
Check the machine controls to make sure that they move freely and have automatically returned
to the neutral position.
Operating Instructions
⚠
WARNING
•
Only operate in good light, keeping away from holes and hidden hazards.
•
Slow down and use extra care on hillsides. Be sure to travel in the recommended direction on
hillsides. Turf conditions can affect the machine's stability.
•
Slow down and use caution when making turns, crossing roads and sidewalks, and changing
directions on slopes.