background image

E

N

G

LI

S

H

9

INSTALLING THE COUPLER/REGULATOR

Attach the side spout of the regulator to your CO2 tank. Tighten with wrench.

Attach the loose end of one of the Tap Tower hose lines to the top spout of the 

coupler and secure with a hose clamp. Using one of the CO2 Hoses, attach one 

end of hose to one of the bottom outputs of the regulator and secure with a hose 

clamp. Use a third clamp to connect the other end of the hose to the side output 

of the coupler. Repeat steps with second coupler and second CO2 hose. 

 

Use the screw in the center of the regulator to adjust the output pressure. 

When the desired pressure is reached spin the nut to lock in place. 

When the pressure is at the appropriate level, use the tank band 

to fix the CO2 tank to the inside of the kegorator. 

The Regulator works the CO2 Tank and measures PSI (pounds per square inch), as well as 

the volume of the CO2 gas in the cylinder. Set output pressure gauge between 8-12 PSI.

1. 

Close the shut off valve on the regulator, and open the CO2 tank valve completely. 

2. 

If needed, twist the locking nut loose so that the screw can be adjusted. Unlock screw using 

a screwdriver or by hand. Slowly turn the regulator adjustment screw until the desired 

pressure is shown on the output pressure gauge (8-12 PSI). Turning clockwise will increase 

the output pressure, and turning counter-clockwise will decrease the output pressure. 

3. 

Once desired pressure is reached, re-lock the nut with a wrench or by hand.

4. 

Open the CO2 shut-off valve on the regulator to allow gas flow from the regulator to the 

keg coupler. You will hear the keg pressurizing. The output needle will drop momentarily 

until the pressure has equalized. Then the needle will return to the point you set it at.

5. 

The keg coupler is designed with a pressure relief valve (PRV). Pull the ring on the 

PRV briefly to allow gas to vent. This will permit gas to flow through the regulator 

and help obtain a more accurate reading on the output pressure gauge.

6. 

Re-check the output pressure on the regulator, and if necessary re-adjust using step #2 until 

the desired pressure is shown. It is always wise to follow up any adjustment to the regulator 

with a brief pull of the PRV ring to ensure an accurate output reading. 

 

Location of Temperature Control

The temperature control is located in the upper right-hand corner in the front of the  

kegorator

.

Settings are min, normal, max and super cold. 

Pressure Relief Valve

Tank Pressure 

Gauge

 (0-

3000 PSI) for 

measuring PSI 

of CO2 in tank. 

Output Pressure Gauge

 

(0-60 PSI) for measuring PSI 

of CO2 outflow from Tank 

to Keg  

(8-12 PSI recommended).

Screw 

adjusts the 

output pressure. 

CO2 Shut 

Off Valves

Summary of Contents for KEG9000DTSS

Page 1: ...All products are trademarks of Nostalgia Products Group LLC Worldwide design utility patented or patents pending 2012 Nostalgia Products Group LLC www nostalgiaelectrics com rev 08 22 13 2013...

Page 2: ...KEG9000 DTSS DoubleTap Kegorator Instruction Manual...

Page 3: ......

Page 4: ...ANTY 13 SAFETY Appliance Specifications 115V 60Hz 1 47A max amps 6A UL Approved Your safety and the safety of others is very important We have provided many important safety messages in this manual an...

Page 5: ...ly instructions in this manual before it is used See the Parts Assembly section for more details 3 This appliance must be connected to a proper electrical outlet with the correct electrical supply 4 P...

Page 6: ...ecome trapped inside CO2 Carbon Dioxide Gas 1 CO2 gas can be dangerous CO2 cylinders contain high pressure compressed gas which can be hazardous if not handled properly Make sure you read and understa...

Page 7: ...it dimensions L 28 75 x W 21 x H 31 25 not including tap tower Tap tower is 15 from base to highest point of handle The following dimensions are recommended for clearances around the kegorator Sides 1...

Page 8: ...abilize before the power is turned on Allow the kegorator to stand in an upright position for about 8 hours before turning on the power Allow unit to cool for at least 12 hours before purchasing a keg...

Page 9: ...king Casters should be fastened at the front end of the unit 1 Empty the inside of the cabinet completely and lay the kegorator down on its back We recommend that you place a piece of cardboard or clo...

Page 10: ...asher with the holes in the kegeorator and those in the base of the Tap Tower Using the four screws and nuts provided attach the Tap Tower to the top of the kegorator Slide the smaller rubber washer B...

Page 11: ...n on the output pressure gauge 8 12 PSI Turning clockwise will increase the output pressure and turning counter clockwise will decrease the output pressure 3 Once desired pressure is reached re lock t...

Page 12: ...Fig 4 This will open the beer and CO2 gas valves The Keg is now tapped HOWTO OPERATE Follow the steps below to dispense beer 1 Make sure that the kegorator is plugged in properly to a 120V 60Hz 15 Amp...

Page 13: ...ep it in a location where there is proper air circulation and electrical outlets Choose a location where the kegorator will be away from heat and will not be exposed to direct sunlight Foamy Beer Foll...

Page 14: ...any excess beer that is trapped inside helping to prevent any bacteria or mold that could accumulate inside Follow the guidelines below to care for your kegorator when not in use Please adjust the tem...

Page 15: ...90 days of purchase we will repair or replace the unit at our option Our pledge does not apply to damages caused by shipping mishandling or unit being dropped A product deemed defective either from ma...

Page 16: ...ENGLISH 14...

Reviews:

Related manuals for KEG9000DTSS