background image

10

Operating Your KEGORATOR™

Dispensing Beer

Follow the steps below to dispense beer.

1.  Make sure that the KEGORATOR™ is plugged in properly to a 120V, 60Hz, 15Amps 

grounded AC outlet.

2.  Place the drip tray under the beer faucet to avoid messes from excess beer.

3.  Open the beer faucet by pulling the tap towards you to dispense the beer.

NOTE

: If for any reason the beer does not come out of the tap, please refer to theT

apping 

the Beer Keg 

section.

4.  Increase the pressure if the beer runs too slowly.

5.  Hold the glass steady at a 45° angle. When it is 2/3 full, straighten the glass. Proper 

foam should be a tight creamy head and the collar on an average glass should be ¾”  
to 1” high, ideally.

NOTE:

 Only open the CO2 tank 1/4 turn to begin with and then use the regulator to adjust to 

desired pour. If it is not enough, continue to open the CO2 tank by 1/4 turn and use regulator 

until desired setting is reached.

NOTE:

 It is normal to see condensation form on the faucet. It is caused by the difference in 

temperature between the cold beer and the inside of the faucet when beer is flowing through 

the line.

Cleaning & Maintenance

Flushing the tubes

Follow the steps below to clean the keg tap and hoses. (see illustration below)

1. 

Turn off CO2 completely before attempting to clean.

2. 

Remove the hose from the coupler and carefully twist the dispenser faucet off  
the top of the KEGORATOR™.

3. 

Ensure that the dispenser handle is in the 

 

down position before flushing the hose.

 

If this is not set correctly, water cannot flow

 

through. Hold the open end of the hose under

 

running water for 3-5 minutes, while the 

 

beer dispenser faucet drains into the sink. 

 

This will clear any excess beer that is 

 

trapped inside, helping to prevent any

 

bacteria or mold that could accumulate inside.

4. 

In order to clean and remove any excess beer that 

 

may leak into the unit space inside the door, remove 

 

the black rubber insulation and wipe with a wet towel 

 

as needed.

Storage & Care

Follow the guidelines below to care for your KEGORATOR™ when not in use.

• 

Please adjust the temperature control dial to MID or LOW in colder 

 

environments because this unit does not self-defrost and ice may build up inside the  

 

unit. The temperature control dial is located on the back side of the KEGORATOR™  

 

inside the cut out area at the bottom to the lower left.

• 

Always rinse the beer line if you do not intend to use your KEGORATOR

™ for a  

 

period of time. First, turn off the CO2 and dispense beer until it stops. This will release  

 

pressure in the keg so that the coupler can safely be detached. 

• 

To avoid permanent damage to the unit, never use sharp objects inside 

 

 

the KEGORATOR™.

Flush hose with water

2

Detach beer line

1

Summary of Contents for KEGORATOR KRS-2000 SERIES

Page 1: ...Nostalgia Products Group LLC 1471 Partnership Dr Green Bay WI 54303 5685 Visit us online at www nostalgiaelectrics com 2009 Nostalgia Products Group LLC Rev 8 18 09 ...

Page 2: ...KEGORATOR KRS 2000 SERIES INSTRUCTION MANUAL FOR HOUSEHOLD USE ONLY READ THESE INSTRUCTIONS BEFORE USING THIS UNIT SAVE THESE INSTRUCTIONS ...

Page 3: ...eaning or making any repairs 9 We suggest that a certified technician perform the service if for any reason this product requires service 10 If your old appliance is being discarded we recommend that you remove the door and leave the shelves in place This will reduce the possibility of danger to children 11 This appliance should not be recessed or built into an enclosed cabinet It is designed for ...

Page 4: ...y from heat Store extra cylinders in a cool place preferably 70 F Secure fasten with a chain in an upright position when storing 7 Always ventilate and leave the area immediately if CO2 leakage has occurred 8 There are two safety devices in the pressure system in the form of a valve One safety feature is on the CO2 bottle The second is on the regulator 9 Never attempt to refill CO2 cylinder yourse...

Page 5: ...RATOR capacity 4 6 cu ft KEGORATOR unit dimensions 20 3 W x 32 10 H x 26 20 D The following dimensions are recommended for clearances around the KEGORATOR Sides 19 mm Back 1 25 mm KEGORATOR unit weight 77 6 lbs KEGORATOR Specs 115V 50Hz 1 5A max amps 6A Use of Extension Cords Avoid using an extension cord because of potential safety hazards in certain conditions If it is necessary to use an extens...

Page 6: ...on instructions before installing the KEGORATOR If after completing the process you are still unsure whether the KEGORATOR has been properly installed we recommend that you contact a qualified installer Note Allow the KEGORATOR to stand in an upright position for about 8 hours before turning on the power This is very important Once the unit is laid on it s side the Freon in the refrigeration unit ...

Page 7: ...nds per square inch as well as the volume of the Co2 gas in the Cylinder Output Pressure Gauge 0 60 PSI for measuring PSI of CO2 in tank Tank Pressure Gauge 0 3000 PSI for measuring PSI of CO2 outflow from Tank to Keg Screw adjusts the output pressure Pressure Relief Valve ...

Page 8: ... from the coupler prior to STEP 3 Installing the CO2 Regulator and the CO2 Cylinder Follow these steps to safely install the CO2 regulator and CO2 cylinder You must read and understand the following procedures for the CO2 cylinders before installation NOTE If all your rubber washers O rings are not pre installed please refer to your parts list pg 6 NOTE Your CO2 cylinder has DOT USA Department of ...

Page 9: ...erator and the hose line feeds through the bottom attach the wing nut to the coupler O rings on the CO2 line CO2 line to regulator CO2 line to coupler O ring for coupler O ring for regulator O ring for tap Tap tower washer goes in between refrigerator and tap tower CO2 tank band Washers Below are pictures of some of the extra washers that are included with the KEGORATOR and where they belong ...

Page 10: ...he work top Firmly grasp the cabinet plug twist and pull upward Note Keep this plug in a safe place it will be required when using the KEGORATOR as a refrigerator without a beer keg in use 2 There are notches on the bottom of the draft arm assembly that line up with grooves inside the opening in the top of the KEGORATOR Align the draft arm with the opening in the top of the unit then place inside ...

Page 11: ...nto the side of the coupler Attach the CO2 line see step 3 on pg 5 and hand tighten firmly Secure the tank with CO2 tank strap 4 Make sure the beer tower faucet is in the closed handle pointing straight back position before connecting the coupler to the keg To secure the tank connection pull the coupler handle out and push down until it locks into position Listen for the click of the pull handle w...

Page 12: ... completely before attempting to clean 2 Remove the hose from the coupler and carefully twist the dispenser faucet off the top of the KEGORATOR 3 Ensure that the dispenser handle is in the down position before flushing the hose If this is not set correctly water cannot flow through Hold the open end of the hose under running water for 3 5 minutes while the beer dispenser faucet drains into the sin...

Page 13: ...signed and built to provide many years of satisfactory performance under normal household use The distributor pledges to the original owner that should there be any defects in material or workmanship during the first 90 days of purchase we will repair or replace the unit at our option Our pledge does not apply to damages caused by shipping mishandling or unit being dropped A product deemed defecti...

Page 14: ...12 ...

Page 15: ...13 ...