13
Simplex 4010 NION Installation/Operation Manual Version 2 Document 51998 Rev. A1 03/26/03
Style-7 Network with Local Area Servers on Separate Computers
Style-7 Network with Local Area Servers on Separate Computers
Style-7 Network with Local Area Servers on Separate Computers
Style-7 Network with Local Area Servers on Separate Computers
Style-7 Network with Local Area Servers on Separate Computers
Local Area Server 1
Local Area Server 1
Local Area Server 1
Local Area Server 1
Local Area Server 1
(Primary
(Primary
(Primary
(Primary
(Primary
)))))
Echelon Network
Echelon Network
Echelon Network
Echelon Network
Echelon Network
Ethernet
Ethernet
Ethernet
Ethernet
Ethernet
S7FTXC-PCA (Style-7) Network Transceiver
The S7FTXC-PCA combines two FT-10 interface ports that allow the transceiver to meet Style-7 wiring requirements.
The two ports on the S7FTXC-PCA, when used with true style-7 wiring requirements, create a point-to-point type
network segment allowing up to 8,000 feet between nodes that use the S7FTXC-PCA. The separate FT ports allow
two twisted pair connections so that a cabling fault on one segment will not affect the other.
The S7FTXC-PCA has four diagnostic LEDs that are visible when the board is installed onto a NION.
•
Packet - Blinks when a packet is received or transmitted.
•
Status - Blinks steadily when no network traffic is present and blinks rapidly when processing.
•
P1 ERR and P2 ERR - These LEDs (P1 for Port1, P2 for Port 2) denote error conditions when they blink.
NOTE: The S7FTXC temporarily stops processing when an error occurs. This suppresses noise propagation throughout the network
.
Figure 1-5: Sample Style-7 Networks
For more information about Style-7 network configuration refer to the Local Area Server manual 51544.
Local Area Server 1
Local Area Server 1
Local Area Server 1
Local Area Server 1
Local Area Server 1
(Primary
(Primary
(Primary
(Primary
(Primary
)))))
Local Area Server 2
Local Area Server 2
Local Area Server 2
Local Area Server 2
Local Area Server 2
(Secondary)
(Secondary)
(Secondary)
(Secondary)
(Secondary)
Echelon Network
Echelon Network
Echelon Network
Echelon Network
Echelon Network
Style-7 Network with Local Area Servers on One Computer
Style-7 Network with Local Area Servers on One Computer
Style-7 Network with Local Area Servers on One Computer
Style-7 Network with Local Area Servers on One Computer
Style-7 Network with Local Area Servers on One Computer
Local Area Server 2
Local Area Server 2
Local Area Server 2
Local Area Server 2
Local Area Server 2
(Secondary)
(Secondary)
(Secondary)
(Secondary)
(Secondary)
NOTE: When using the S7FTXC with a NION-232B, relay 2 on the NION-232B (LED D13) will activate
when a wire fault is detected by the S7FTXC. When used with a Simplex 4010 NION LED D2 will light.
S7FTXC
S7FTXC
S7FTXC
S7FTXC
S7FTXC
Style 7 FT-10 Transceiver
Header Connection
Port 1
Port 2
Packet LED
Status LED
Port 1 Error LED
Port 2 Error LED
Opposite side of S7FTXC
Termination Jumper
( Port 2)
Termination Jumper
(Port 1)
Figure 1-4: S7FTXC-PCA Style 7 Transceiver
Bus Termination
FT Termination
Bus Termination
FT Termination
NOTE: See section 1.1.8 of the Network
Installation manual 51539 for more infor-
mation about FT and Bus termination.
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com