background image

2

Welcome to the world of smart climate control. We are pleased you have cho-
sen the 

intelligent Growing Systems

iGS-

110

product to benefit from the

added yield and quality climate controlled environments can give you ! Apart
from its reliability and precision, you will benefit from incorporated smart fea-
tures that will work with you to optimize your climate control.

The first part of this manual aims at giving you a quick start and a global
overview of all basic functions and configuration options. The second part will
give you a more detailed explanation on the control loops, configuration
options and smart features that the iGS-

110

works with. 

We are always interested in any comments or suggestions you might have.
Feel free to let us know at the following e-mail : info@novabiomatique.com.

TABLE OF CONTENTS

Part-

1

Setting up the controller

3

Contents and description of the iGS-

110 

Temp/RH smart controller

3

Tips on proper installation

4

Controller Outputs

5

Output 

1

: Temperature control

5

Output 

2

:  Humidity control

5

Output 

1

: Mixed control

6

Setting operating modes for output 

1

and 

2

6

Selecting the temperature units

7

Adjusting Day and Night Setpoint values

7

Display functions

7

Displaying the Dynamic Differential

8

Part-

2

More on the iGS-

110

Temp/RH smart controller

8

Temperature control sequence

8

Humidity control sequence

8

Mixed Temperature and Humidity Control Sequence

9

Dynamic Differential

9

Controller Hints

10

Error Messages

11

Maintenance and warnings

11

iGS-

110

Specifications

11

iGS-

50

Specifications

11

Safety notice

12

Product warranty

12

Product repairs

12

iGS-

110

Operating Modes

13

Temperature Control Modes

13

Relative Humidity Control Modes

14

Summary of Contents for Intelligent Growing Systems iGS-110

Page 1: ......

Page 2: ...know at the following e mail info novabiomatique com TABLE OF CONTENTS Part 1 Setting up the controller 3 Contents and description of the iGS 110 Temp RH smart controller 3 Tips on proper installatio...

Page 3: ...n Once recon nected the controller will reboot All operating modes and values entered before the interruption will be retrieved automatically from memory Also refer to the safety notice on page 12 Now...

Page 4: ...ture output can also be configured to be independent or depen dent of the humidity output When independent output 1 will control the heater cooler without considering the actual humidity output status...

Page 5: ...ty 8 When you chose the controller to control RH or Temp levels day and night the controller will use the setpoint value during the day and the night setpoint value during the night even when in day a...

Page 6: ...the Output 1 will activate the equipment as soon as the temperature is above the temperature setpoint OR the humidity is above the humidity setpoint However the Output 1 will not be deactivated until...

Page 7: ...except in the case of a repair covered by the warranty where Nova Biomatique inc will assume the return shipping fees only To send for repairs or upgrades you must call for a product return number Thi...

Page 8: ...output OFF while TEMP is ON NIght 42 Turn RH output OFF while TEMP is ON 5 min Dehumidifier 43 Turn RH output OFF while TEMP is ON 10 min 44 RH output is fully independent of TEMP control 51 Turn RH...

Page 9: ...Printed in Canada Nova Biomatique Inc Revision 1 30...