novaG-A
Manual Service
8/25
1.2 Issue
Ref. NR-00016-ENG
5.
Open the manual air valve
6.
Pressurise the unit and make sure there are no leaks.
7.
Activate the trigger several times to make sure the mix chamber moves correctly.
8.
Make sure that the pressure in the machine and the temperature of the heaters and the
hoses are correct (see the Machine Service Manual).
9.
Completely open the manual valves of each product by turning them anti-clockwise.
10.
Press the blocking device and turn it anticlockwise to leave it in projection mode or
position.
11.
Perform a test projection in a vessel
WARNING:
Before carrying out maintenance, repair or cleaning work, press the
blocking device and turn it clockwise to leave it in blocking position or mode. Always
remove the coupling block from the gun, completely close the manual product input
valves and disconnect the air supply to avoid any possible accident.