background image

 

Instruction Sheet

 

NovaLynx Corporation

  PO Box 240 Grass Valley CA 95945 

DOC 110-WS-25N IS 20210503

 

Phone (530) 823-7185

 

www.novalynx.com 

110-WS-25N Quick Start 

 

Hardware Installation 

Select a level area on firm ground that will support the tripod. The area 
should be away from buildings or trees that block air movement. A grassy 
area is preferred as sunlight reflected from gravel or pavement could elevate 
the temperature readings. If high winds are expected the legs of the tripod 
must be secured to prevent tipping over. 
1.

 

Open the tripod to the fullest extent and secure it. 

2.

 

Assemble the wind sensor on the swaged end of the 5' mast. Secure it 
with the two screws on the base of the sensor. Notice the NORTH label 
on the base of the wind sensor. 

3.

 

Assemble the mast to the tripod. Rotate the mast until the NORTH label 
points north. Tighten the mounting screws on the tripod. 

4.

 

Mount the temperature/humidity sensor on the mast, leaving room for 
the remaining equipment. 

Note: the barometric pressure sensor is pre-

installed in the NEMA enclosure.

 

5.

 

Install the rain gauge on the opposite side of the mast. 

6.

 

Mount the NEMA data logger enclosure just above the top of the tripod 
or on a leg of the tripod, as desired.  

 

Wiring 

Route each sensor wire into the NEMA enclosure through the conduit fitting on the bottom. Attach an earth 
grounding wire to the copper lug on the bottom of the enclosure. Connect the other end of the wire to an 
earth grounding rod (NovaLynx 190-110 Grounding Kit, sold separately). 

1

2

3

4

5

6

7

8

A3

GND

5 Vref

A4

A5

A6

A7

GND

W

in

&

 R

ai

n

Te

m

/ R

H

 / 

B

/ A

U

X

Wind Sensor

200-WS-02F

Speed Signal

Excitation

Direction Signal

Direction GND

Speed GND

Shield

Signal

GND

Barometric Pressure

110-WS-25BP

GND

Vin

BP Signal

Temperature & Humidity

110-WS-25THA

Shield

Vin

Temp Signal

Humidity Signal

GND

Rain Gauge

110-WS-25RG

( BLACK )

( RED )

( RED )

( BLACK )

( GREEN )

( SILVER )

( BLACK )

( GREEN )

( WHITE )

( RED )

( WHITE )

( RED )

( BLACK )

( SILVER )

( BROWN )

( WHITE )

An0

An1

An2

GND

5 Vref

A1

A2

GND

1

2

3

4

5

6

7

8

DWG 890-0097-01

Earth Ground Lug

 

110-WS-25N Weather Station 

Reviews: