C-Series IM 1 MAY 2014
7.2 Electrical Installation
Always disconnect and lock out the main power supply before wiring power and control cables
between the NC rotary knife cutter controller and the external devices. Refer to the wiring
diagram and general arrangement drawings supplied with this system before making electrical
connections.
Use shielded cable for communications wiring.
Keep communication cables and control wiring as far as possible from high voltage
equipment. If you must run cable across power lines, run the cable at right angles to the
line.
Ensure the equipment grounding is properly connected. Shielded cable should be
grounded at one end only and is typically grounded in the main I/O enclosure.
WARNING:
Do not install communication cable where it will
come into contact with any buildup of electrical charge!
It may be tempting to run the wire next to the material conveying
lines, but a substantial buildup of electrical charge can and will occur,
especially with certain types of plastic resins and, if the conveying
lines are not grounded, they can arc to the cable disrupting
communications and/or possibly causing damage.
Open the cutter’s electrical enclosure and insert the main power through a knockout in the
wall of the enclosure. Connect the power wire as indicated on the included wiring diagram.
Check that all terminal screws are secure. Close electrical enclosure.
12
© 2015 NOVATEC Inc. All Rights Reserved
Document: C-Series 7 MAY 2015