13.7 SETUP Screen 3
All items on this page require setup authorization except for Exit HMI and background color.
PROCESS LIMITS
– Determine the blade speed limits and the points at
which the cutter will switch between On Demand and Continuous Mode.
Max Cut Rate Demand
– This determines the minimum time between on
Demand cuts. It also determines when the system should switch to
continuous mode.
•
Min Blade Speed Demand
– Sets the minimum speed that can be
entered as the On Demand blade speed on the recipe screen.
Min Blade Speed Cont
– Sets the minimum permissible RPM of the
blade in continuous mode. Typically this is set to a value which can still give a good cut to the
product.
Max On Demand Blade Speed
– This sets the maximum blade speed for On Demand cutting. This
will be limited by the max motor speed and is typically set by NOVATEC so that the drive does not
fault when accelerating and decelerating and the overall system can handle the forces of the blade
motion.
Note: It is possible to make settings where there are line speeds that cannot be handled by Max
On Demand CPM or Minimum Continuous Mode blade speed.
The Max continuous speed is the max speed of the motor and the gear box. It is possible to run
the continuous speed so fast that when it stops or transitions to On Demand Mode, the drive
faults.
32
© 2015 NOVATEC Inc. All Rights Reserved
Document: C-Series 7 MAY 2015