C-Series IM 1 MAY 2014
13.9 Batch Counter Screens
(Accessed through Home Screen)
Counter Screen with Box Count Disabled Counter Screen with Box Count Enabled
Most of the fields are duplicates of what is on the Quick Ops screen. The following explains the extra
buttons.
Count Reset -
Press and hold to reset the counters.
Warnings and Alarms -
Signals can be set to activate a warning
message or sound a siren when production reaches a certain point.
The system calculates the time remaining at the current production
rate and determines if the alarm should activate. Set the time in
minutes and tenths of minutes and the event to activate the alarm
which can be Never, End Of Box, End of Production, or Both. The
Warning Alarm will active a warning message the same way as any other. The Alarm Siren activates
the horn only which can be silenced on the Quick Ops Screen. The siren must be configured in the
system set up to activate.
At End of Box:
- (Requires box count to be enabled). Used to determine
the action of the cutter when the part count has reached the end of box.
At End of Production: –
Used to determine the action of cutter when the
part count has reached the total pieces setting.
Continue
– The cutter keeps cutting the same product and
counter keeps incrementing
Cut Scrap
– If scrap mode is Enabled, the cutter will execute the scrap
recipe and the counter will not increment.
Stop –
The cutter will stop.
Enable/Disable Box Count
- Press this button to change the counting mode. Box count
is enabled if the button is bright.
36
© 2015 NOVATEC Inc. All Rights Reserved
Document: C-Series 7 MAY 2015