background image

- 4 - 

RN-101M 

  

                                                                                                                        

NOVATEK-ELECTRO

 

When the current overload protection breaker trips, the load is disconnected from the mains,  the LOAD 

LED flickers, and the display shows the monitored voltage value. In this case, in order to connect load, the 
protection breaker needs to be switched ON. The miniature circuit breaker reset button is at the top of the 
device (black button). It will come up in short circuit condition and needs to be pressed down for resetting. 

 
To avoid undesired fault tripping to minor and/or short-term undervoltage, the fixed minimal voltage 

tripping time delay function is provided (7 s). When deep undervoltage occurs (more than 60V below minimal 
voltage setting ore voltage drops below 165V), the relay trips within 0.12 sec. 

 

When the relay is energized, the display shows “StA” indication shortly, and then the relay switches to the 

AR delay mode. 

 

5  WARRANTY  

 

 The manufacturer guarantees trouble-free operation of RN-101M device within thirty six months after the 

date of  sale on the following conditions: 

       - proper installation; 
       - manufacturer’s QC department inspection seal is intact; 
       - integrity of the device case, no traces of mechanical damage, case opening, cracks, chipping, etc. 

 

 

 

 