background image

- 7 - 

NOVATEK-ELECTRO

                                                                                     REV-201М

     

                                                                                                                                                       

 

      ATTENTION!!! 

-

 

In  this  mode  of  operation  time  adjustment  knobs  (

T1

  and 

T2

)  as  well  as  the  DIP  switched  for  the  time 

ranges (

D1

 and 

D2

) doesn’t function. All timing frames and intervals are preprogrammed and fixed. On special 

customer  request for the algorithm  “START-PAUSE-START”  it’s  possible to change the timing  intervals  and 
delays as per requirement 

-

 

REV-201M has internally preprogrammed block t

hat doesn’t allow to turn 

ON

 the power load on 

Channel 2

 

until output contacts of 

Channel 1

 are being closed (

ON

). 

 

1.3.3.5

  

“Impulse 2”.

 

 In the figure 6 there is represented the working algorithm of relay "Impulse 2

”. 

 

 

Figure 6

– The working algorithm of relay "Impulse 2” 

 

Time counting on each channel begins from the moment of power supply to the terminals «L1-N» (channel 1) 

and «L2-N» (channel 2). The time delay is adjusted by the potentiometer knobs 3,5,10,12 (figure 1). Each channel 
has two time setting adjustments 

T1

 and 

T2

. The channel cutting off delay is defined by sum of delays arranged by 

two potentiometers (

T1 + T2

). 

At power supply on the channel there switches the load relay on, a red LED of this channel is on and the time 

reading begins 

T1 + T2

. After delay time period the load relay switches off, the LED changes the light to green and 

the relay turns in standby mode. 

The restart of relay is made after de-energizing and energizing again of power supply. 

 

1.3.3.6

 

Intermittent 2 

 

In the figure 7 

is resulted the working algorithm of relay “

Intermittent 2

” 

 

”. 

 

 

Figure 7

– The working algorithm of relay “

Intermittent 2

”  

 

Time reading on each channel begins from the moment of power supply to the terminals 

«L1-N» (channel 1) and 

«L2-N» (channel 2). Each channel has two setting adjustments T1 и T2. 

At energizing the power supply to the channel the load relay switches on and the time reading T1 starts, adjusted 

by the knobs of potentiometers 12, 3 (figure 1) for the 1-st and 2-nd channels correspondently 

– time of work. The 

red LED of the channel is on. 

After the end of delay time period T1, the load relay switches off and the time reading T2 begins, arranged by 

potentiometers knobs 5, 10 (figure 1) for the 1-st and the 2-nd channels correspondently 

– time of pause. The LED 

of the channel changes the light to green color. 

After the end of delay time period T2, the load relay switches on, the LED changes color to the red one and the 

cycle of relay work is restarted (the delay time reading 

Т1 begins and so on). 

 

Summary of Contents for REV-201?

Page 1: ...NOVATEK ELECTRO Ltd Intelligent industrial electronics MULTIFUNCTIONAL TWO CHANNEL TIME DELAY RELAY REV 201 OPERATING MANUAL Review the Operating manual before using the unit www novatek electro com...

Page 2: ...PT TO REMOVE AND REPAIR THE UNIT Some of the unit components may be live NEVER ATTEMPT TO OPERATE THE UNIT WITH THE MECHANICAL DAMAGE OF THE HOUSING The unit is not designed for operation under impact...

Page 3: ...ioning in one compact case housing 2 time delay relays in one case Mode 2 Parallel operation of the channels To each of two channels the power supply is applied simultaneously Thus the time countdown...

Page 4: ...more then 0 150 Outer dimensions Figure1 Operation temperature range from 30 to 55 Storage temperature from 45 to 60 Arbitrary mounting position Standard 35 mm DIN rail mounting Electrical characteris...

Page 5: ...the power supply source is applied to the input terminals L1 N Channel 1 L2 N Channel 2 Time delay setting is selected using the knobs of potentiometers 3 5 10 12 figure 1 Each channel has two adjusta...

Page 6: ...further Note if the time interval of potentiometer 2 is equal to zero the load relay will not switch over 1 3 3 4 Control pre starting signalization operation function Figure 5 The working algorithm o...

Page 7: ...ED of this channel is on and the time reading begins T1 T2 After delay time period the load relay switches off the LED changes the light to green and the relay turns in standby mode The restart of rel...

Page 8: ...s mode the supply voltage of the second channel is used as the main power supply for the relay and the power input of the first channel is used as the control signal 2 GENERAL USE AND APPLICATION 2 1...

Page 9: ...this time interval T1 the relay contacts get open and starts the timing countdown of set time interval T2 After the termination of the T2 timing countdown REV 201M starts and the process keep on work...

Page 10: ...t is strictly prohibited to use simultaneously both power supply inputs for 24V DC and mains 230 240 VAC Only one power supply input should be used 2 2 USAGE AND OPERATION OF REV 201M Connect the powe...

Page 11: ...shall provide a free repair of the unit within the warranty period if all the provisions of user manual were complied with by the consumer The unit shall not be subject to warranty service in the foll...