Sending Firmware Data
It can take 30 minutes to 1 hour to complete sending the entire firmware to the receiver. RealTerm is preferred,
but other terminal programs may be used (at user’s discretion).
1. Download RealTerm from:
sourceforge.net/projects/realterm/
.
2. Open RealTerm, go to the Port tab.
3. Choose the COM port to be used (if using USB or Serial) along with the appropriate baud rate. If using
Ethernet, type the IP address right where the Port dropdown menu is. Baud rate is not required to be
specified if using Ethernet.
If using ICOM (Ethernet), ensure the Winsock option is set to Raw, otherwise the binary part
of firmware will be encoded and produce CRC errors. This is not necessary if connecting via
serial or USB.
If using ICOM (Ethernet), a connection will be verified by the [ICOM1] string showing up at
the top.
If using serial or USB, screen will appear empty.
4. Go to the
Send
tab. Click on the ellipsis button to the right of the
Dump File to Port
drop down menu.