APPENDIX A CPT7 Technical Specifications
CPT7 and CPT7700 Installation and Operation User Manual v12
175
A.6 CPT7 Data Communication Specifications
COM1
Electrical format
RS-232
Data rates
2400, 4800, 9600 (default), 19200, 38400, 57600, 115200 , 230400 or 460800 bit/s.
1
Signals supported
COM1_Tx, COM1_Rx
CPT7 port
IO2
Connector on Cable
DB9 female
(on the CPT7 I/O2 Cable)
COM2
Electrical format
RS-422
Data rates
2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, 230400 or 460800 bit/s.
Signals supported
, COM2_Tx-, , COM2_Rx-
CPT7 port
IO1
Connector on Cable
DB9 female
(on CPT7 I/O1 Cable)
CAN Bus
Electrical Format
ISO 11898-2
Data rates
1 Mbps maximum.
CAN Bus throughput is determined by slowest device on the bus
CPT7 port
IO2
USB
Electrical format
Conforms to USB 2.0
Data rates
Hi-speed (480 Mb/s)
CPT7 port
IO2
ETHERNET
Physical layer
10BASE-T/100BASE-TX
CPT7 port
IO2
Table 33: Data Communications Interfaces
1