APPENDIX A CPT7 Technical Specifications
CPT7 and CPT7700 Installation and Operation User Manual v12
172
A.5 CPT7 Electrical and Environmental Specifications
Operating Temperature
-40°C to +71°C
Storage Temperature
-40°C to +85°C
Humidity
95% non-condensing
Submersion
2 m for 12 hours (IEC 60529 IPX8)
Water Resistance
MIL-STD-810H, Method 512.6
Dust Resistance
MIL-STD-810H, Method 510.7
IEC 60529 IP6X
Random Vibration
MIL-STD-810H, Method 514.8, Category 24, 7.7 g RMS
Sinusoidal Vibration
IEC 60068-2-6
Bump
IEC 60068-2-27 Ea (25 g)
Shock – Operating
MIL-STD-810H, Method 516.8, Procedure 1, 40 g, 11 ms terminal sawtooth
Acceleration
MIL-STD-810H, Method 513.8, Procedure II (G Loading - 15 g)
Table 29: CPT7 Environmental Specifications
Voltage
+9 to +36 VDC
Power
Consumption
9 W typical, all constellations, all frequencies, plus L-Band
These are typical values using serial ports without interference mitigation. These
values can change with the number of satellites in view, firmware version, data
logging rates and features in use. Use them as a guide for what you might
expect but not as absolute values
Inrush Current
5 A for less than 1.3 ms (@ 12 V; typical)
Table 30: CPT7 Power Requirements
Antenna Connectors
SMA female, 50 Ω nominal impedance
Table 31: CPT7 RF Input/LNA Power Output