Chapter 3 OEM7 Receiver Operation
CPT7 and CPT7700 Installation and Operation User Manual v12
59
Figure 17: Transfer FINE Time from Fine Clock to Cold Clock Receiver
Transfer FINE Time from a Fine Clock to a Warm Clock GPS Receiver
1. Connect the 1 PPS signal of the fine clock receiver to the Mark 1 input (Event1) of the warm clock receiver
as shown in
Figure 18: Transfer FINE Time from Fine Clock to Warm Clock Receiver
2. Issue the following command to the warm clock receiver:
adjust1pps mark
The phase of the warm clock receiver clock is adjusted by the fractional measurement of the fine clock
receiver’s 1 PPS mark input event. In other words, it synchronizes the warm clock receiver’s 1 PPS to the
incoming 1 PPS of the fine clock receiver. It does not adjust the one second TOW counter or the receiver’s