Operation OEM6 Cards and Enclosures
Chapter 4
OEM6 Family Installation and Operation User Manual Rev 12
71
Transfer FINE Time from a Fine Clock to a Warm Clock GPS Receiver
1. Connect the 1 PPS signal of the fine clock receiver to the Mark 1 input (Event1) of the warm clock
receiver as shown in
Figure 32, Transfer FINE Time from Fine Clock to Warm Clock Receiver
Figure 32: Transfer FINE Time from Fine Clock to Warm Clock Receiver
2. Issue the following command to the warm clock receiver:
adjust1pps mark
The phase of the warm clock receiver clock is adjusted by the fractional measurement of the fine clock
receiver’s 1 PPS mark input event. In other words, it synchronizes the warm clock receiver’s 1 PPS to the
incoming 1 PPS of the fine clock receiver. It does not adjust the one second TOW counter or the receiver’s
week number. This procedure is used to make small corrections to the warm clock receiver’s clock.
If Receiver 2 is not in coarsetime, the input is ignored.
Fine Clock
Warm Clock