Data Logs
Appendix C
SPAN-SE User Manual Rev 1
257
An RXSTATUS log with a component hardware error:
#RXSTATUSA,COM1,0,99.5,FINESTEERING,1521,319470.627,40000021,0000,143;
80000000,4,40000021,00000000,00000000,00000000,00000000,00000000,00000000,000
00000,00000020,00000000,00000000,00000000,00000000,00000000,00000000,00000000
*dd24b521
The error bit 80000000 indicates a component hardware error. This means the OEMV-3 is not
communicating. This is a non-recoverable error for SPAN-SE. It indicates that the OEMV-3 has
experienced a USB overrun, or that the OEMV-3 is no longer powered. Since SPAN-SE controls
the power to its internal OEMV-3, it is unlikely the OEMV-3 has lost power. It is more likely that
the user has overloaded the OEMV-3 USB with excessive log requests. In this case, the
RXSTATUSEVENT log would show:
#RXSTATUSEVENTA,COM1,0,0.0,FINESTEERING,1521,319470.627,404c0028,0000,143;
ERROR,31,SET,"Component Hardware Failure"*79a2006b
Table 65: SPAN Receiver Error
Nibble #
Bit #
Mask
Description
Bit = 0
Bit = 1
N0
0
0x00000001
SDRAM Status
OK
Error
1
0x00000002
Firmware Status
OK
Error
2
0x00000004
ROM Status
OK
Error
3
0x00000008
FPGA Status
OK
Error
N1
4
0x00000010
Electronic Serial Number (ESN) access status
OK
Error
5
0x00000020
Authorization Code Status
OK
Error
6
0x00000040
Slow ADC Status
OK
Error
7
0x00000080
Supply Voltage Status
OK
Error
N2
8
0x00000100
Thermometer Status
OK
Error
9
0x00000200
Temperature Status
OK
Error
10
0x00000400
MINOS5 Status
OK
Error
11
0x00000800
PLL RF1 Hardware Status - L1
OK
Error
N3
12
0x00001000
PLL RF2 Hardware Status - L2
OK
Error
13
0x00002000
RF1 Hardware Status - L1
OK
Error
14
0x00004000
RF2 Hardware Status - L2
OK
Error
15
0x00008000
NVM status
OK
Error
Continued on Page 258