The following symbols are found on the system. Study the meaning of the symbols and always use
the equipment in the safest possible manner.
Symbol Explanation
Indicates that the surface becomes hot, and should not be touched with bare hands
。
Indicates that the high voltage (upper 1KV) inside, improper handing could result in an
electric shock to the use.
Before use, carefully read the user manual .Improper handing could result in personal
injury to the user and/or damage to the equipment.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
● This manual is written for the XSZ-107T with an epi-fluorescent attachment YX-2 and before
equipping it with any other ordinary microscope, be sure to learn how to use the microscope.
3.
Maintenance and care
3.1
All the lenses have been adjusted properly, please do not dismount any lenses by oneself as this
will render any warranties / guarantees void.
3.2
The nosepiece and coarse / fine focus parts are very delicate and should under no
circumstances be dismantled by anyone who has not received correct training on how to repair
any faults that may occur.
3.3
Keep the units clean at all times. Do not place any hazardous chemicals near the units as the
lenses will get damaged and shall not be replaced under warranty.
3.4
If, under certain circumstances, certain contaminants end up on the lenses (i.e fingerprints, oil
smudges) one can clean these off with a soft cloth, tissue paper or gauze which has been slightly
immersed in pure alcohol or ether.
Note that the alcohol or ether is extremely flammable;
please take extra precaution when using this method by keeping the cleaning solution and
cloth or material away from potential sources of electrical spark or fire.
3.5
Do not attempt to use any organic (live) solvents to clean the microscope or epi-florescence
unit and other glass components. To clean the microscope and exterior of the epi-florescence
unit, use of a lint-free, soft cloth slightly moistened with a diluted neutral detergent.
3.6
While in use, if at any moment, some liquid of any form splashes onto the microscope,
immediately switch the unit off and remove any liquid that may still be visible.
3.7
Do not dis-assemble any parts of the microscope or the epi-florescence unit as this will
compromise the function or reduce the overall performance of the unit.
3.8
Always place the unit in a cool, dry level surfaced location. When not in use, keep the unit
covered with the provided dust cover and make sure that the microscope as well as attached
epi-florescence unit has sufficiently cooled before storing away
.