For details, see
Section 6.9, “Consolidating Data to or from a NetWare 5.1
Cluster,” on page 57
.
Unloading NUWAGENT.NLM on an Nterprise Branch Office Appliance
Problem: When running the Server Consolidation Utility in conjunction with an
Nterprise Branch Office appliance, if an error state occurs and you are asked to
unload
nuwagent.nlm
, the system might not allow you to unload the
module.
Action: Perform a reboot of the Nterprise Branch Office appliance.
Errors When Connecting to a NetWare 4 Server
Problem: When attempting to connect to a NetWare 4 server, any of the following types
of errors are returned:
An error occurred opening the file.
filename
was invalid.
Error opening connection to SMDR.
The name spaces couldn’t be checked.
8998 error. NWGetVolumeNumber.
Action: There are several actions to take if errors are returned when trying to connect
to a NetWare 4 server, including the following:
If your source server is NetWare 4, make sure that you have IPX
TM
on
your client. For information on verifying IPX on your client, see
Section 6.11.3, “Verifying IPX Is Bound on the Client,” on page 60
.
Add a mapped drive to the source server.
Ensure that SLP is configured properly on the servers involved in the
consolidation project.
Problem: NetWare 6.5 won't communicate with NetWare 4 during a consolidation. IPX
was not installed during the NetWare 6.5 installation.
Action: Add IPX to the NetWare 6.5 server after the NetWare 6.5 installation is
complete.
1
Enter
edit sys:system/autoexec.ncf
at the NetWare 6.5 server
console.
2
Add the server ID of the source server and save the autoexec.ncf file.
Problem: IPX connection is not communicating.
Action: Ensure that there is an IPX connection to the server.
To verify that the source and destination servers can see each other via IPX:
1
On the server console of the destination server, enter
serverid
xxxxx
, where
xxxxx
is the unique server ID number for the server.
2
Enter
load ipxping
.
3
Enter the internal IPX number of the source server.