EN
7.1
7.2
Instruction
Weld the anchors on the leveller to the reinforcement or the dowels.
Health hazard when welding galvanised components:
Welding galvanised parts produces vapours which can be harmful to health if inhaled.
To avoid this, grind the zinc coating off the parts that are to be welded.
General instruction: The image may differ at detail level.
Instruction
Before pouring the liquid concrete, the area adjoining the leveller must be shuttered in on site. We recommend covering
the platform with a protective film before pouring the concrete. Pour the liquid concrete. Ensure use of a suitable grade of
concrete, at least C20/25. In the case of a significant casting height, make sure that the side loads caused by pouring and
compacting do not become excessive. Excessive loads could distort the side walls.
General instruction: The image may differ at detail level.
7. Final installation actions
This installation manual must be given to the customer and kept safely during the entire period of use!