3.2
Technical data
Nominal load according to EN 1398
60 kN
Voltage supply
3 N~, 400 V, 50 Hz, 16 A
Motor
•
Power
1.1 kW / 1.5 kW
•
Operating mode
S3
•
max. duty cycle
20 %
Protection type
IP 65
Permissible inclination of the dock leveller platform
according to EN 1398
12.5 % (7°)
Permissible ambient temperature during operation
−20 °C ... +40 °C
Maximum permissible traversing speed
7 km/h
Sound pressure level L
pA
< 70 dB(A)
3.2.1 Door dimensions
LL
NL
GL
OL
B
BH
A
NW
Fig. 3:
Exemplary representation, illustration may deviate from the product
OL
Overall length (NL + LL)
HL (LL)
Length of lip leveller
IL (GL)
Inclination length (OL - 140 mm)
DH (BH)
Design height
NL
Nominal length
A
Upper bridging
NW
Nominal width
B
Lower bridging
NL
DH (BH)
A (LL = 500)
B (LL = 500)
A (LL = 1000)
B (LL = 1000)
2000
600
330
300
405
315
700
360
400
440
435
2500
600
430
290
500
280
700
470
370
540
390
3000
600
420
270
475
260
700
480
400
565
390
NW:
1750, 2000, 2250 and 2400 for all sizes
All dimensions in mm.