5

The brightness of screen illumination can be adjusted with ring 15.

To make an adjustment of camera one should read a service manual 

for camera. 

To  remove  a  camera  from  monocular  one  should  make  all  above 

points in the other way.

Fig. 3

 Mounting of camera on monocular

Summary of Contents for HELIOS - 01

Page 1: ... PRODUCTION AMALGAMATION NOVOSIBIRSK INSTRUMENT MAKING PLANT NIGHT VISION MONOCULAR HELIOS 01 SERVICE MANUAL 3 803 106 РЭ ...

Page 2: ...Standard Equipment 8 4 Design and Principle of Operation 8 5 Preparation for Operation and Order of Operation 12 6 Maintenance 18 7 Rules of Storage 18 8 Possible Troubles and Trouble Shooting 19 9 Acceptance Certificate 20 10 Warranty 21 12 03 10 05 06 ...

Page 3: ... The monocular is subject to continuous development and improvement consequently it may incorporate minor changes in detail from the information contained herein ...

Page 4: ...and M37x0 75 which are allow to mount a monocular on camera and video camera and to operate at night An eyepiece of monocular has a diopter laying which allows adjusting it by user s eye Electrical diagram of monocular allow to protect am image converter from the intensive light at night If bright lighting gets into the monocular objective the screen of the image converter goes out for some period...

Page 5: ...us 40 C to 40 C and relative humidity of maximum 80 at the temperature of 25 C The monocular is not injurious to health It is not necessary to take special measures to protect a user Apresent of small spots on the screen have not influence on operation of product ...

Page 6: ...ing DO NOT DISASSEMBLE A PRODUCT AND SWITCH IT DO NOT CONNECT THE PRODUCT TO SUPPLY UNIT WITH TENSION MORE THAN 1 5V DO NOT SWITCH THE MONOCULAR ON IN DAYLIGHT WITH THE PROTECTIVE LENS COVER REMOVED DO NOT DIRECT THE MONOCULAR AT BRIGHT SOURCES OF LIGHT ...

Page 7: ...ess 20 Magnification in the center of field of view fold not less 1 8 Range of diopter laying of eyepiece diopter not less 4 Range of objective focusing m 0 5 Time of switching sec not less 2 Supply unit two A 316 AA dry batteries Voltage supply at the temperature of 20 5 C mA not more without illuminator 30 with illuminator 125 Mass kg not less without bag 0 915 with bag 1 115 Overall dimensions ...

Page 8: ... monocular is a complex optoelectronics system for individual use Its principle of operation is based on conversion intensification of the image of an objects of low brightness into the visible image at night by natural light of Moon the stars and so on as well as conversion intensification of IR illumination of various objects to be invisible by eye into the visible one The user sees a magnified ...

Page 9: ... The monocular consists of an objective lens 3 Fig 1 eyepiece 10 and body 6 The body 6 contains an image converter and two battery housings 5 Fig 1 General view 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 10: ...rical diagram of monocular allows to protect am image converter from the intensive light at night If bright lighting gets into the monocular objective the screen of the image converter goes out for some period of time For convenience the monocular is supplied with a belt 7 and a carrying bag The monocular light filter and two cells are packed into the carrying bag The light filter 2 is intended fo...

Page 11: ...11 monocular Monocular is completed with strap 7 and bag The design of the product allows using other photoobjectives which have an operating length of 45 5 mm and connecting size of M 42x1 ...

Page 12: ...the phosphor screen which is due to appear not later that in 2 seconds after the monocular has been switched on The monocular can operate without light filter at night To use a monocular at night it is necessary to shut a diaphragm rotating a ring 15 and to switch the monocular pressing a button 8 The brightness of screen illumination can be adjusted with diaphragm to be located in objective lens ...

Page 13: ...and the monocular is to be put into the case When using the monocular together with a camera it is necessary to screw up an eyeshield 12 from eyepiece 10 screw an adapter 13 in theeyepiece of monocular Fig 2 open a diaphragm of objective lens connect the camera to monocular as it is shown on figure 3 switch a monocular Rotating a ring 11 of eyepiece 10 and ring of objective lens of monocular and c...

Page 14: ...14 Fig 2 Mounting of adapter on monocular ...

Page 15: ...ination can be adjusted with ring 15 To make an adjustment of camera one should read a service manual for camera To remove a camera from monocular one should make all above points in the other way Fig 3 Mounting of camera on monocular ...

Page 16: ...a on eyepiece 10 by thread as it is shown on figure 4 switch a video camera switch a monocular To make an adjustment of video camera one should read a service manual for video camera The brightness of screen illumination can be adjusted with ring 15 To remove a video camera from monocular one should make all above points in the other way When the work is over the batteries are to be removed from t...

Page 17: ...17 Fig 4 Mounting of videocamera on monocular ...

Page 18: ...l is to be used to clean optical surfaces It is not recommended to use other alcoholic substances In non working time the monocular is to be kept in the case 7 RULES OF STORAGE The monocular is to be stored in the heated rooms For long storage it is recommended to remove batteries from the battery housings and keep them in the battery pockets of the carrying case ...

Page 19: ...t order Change the batteries Remove the cover Have the device repaired Week screen luminance The batteries are discharged The objective lens is covered Change the batteries Remove the cover Not sharp image The objective lens or eyepiece are not focused Focus the objective lens and adjust the eyepiece No luminance of the screen in the presence of the bright source of light in the field of view The ...

Page 20: ...CCEPTANCE CERTIFICATE Night Vision Monocular Helios 01 serial _____________ is in compliance with specifications and found fit for service Date of manufacture ______________ Signature _______________________ ...

Page 21: ...peration transportation and storage The claims are not admitted in the event of a failure which is due to careless use violation of the rules of operation transportation and storage The Producer offers a 12 months guarantee since the monocular has been bought if sold by retail or received by the user if not sold by retail The guarantee does not apply to batteries ...