background image

NVG-031TLIB - User’s Manual

 

version 1.2. 

All rights reserved © AAT Holding sp. z o.o.  

 

2

 

INFORMATION 

EMC (2004/108/EC) and LVD (2006/95/EC ) Directives 

 
CE Marking 

 

Our  products  are  manufactured  to  comply  with  the  requirements  of  the  following 
directives and national regulations implementing the directives:  
 



Electromagnetic compatibility EMC 2004/108/EC. 



Low  voltage LVD 2006/95/EC  with  further amendment. The  Directive applies to 
electrical equipment designed for use with a voltage rating of between 50VAC and 
as well as 75VDC and 1500VDC. 

WEEE Directive 2002/96/EC 

Information on Disposal for Users of Waste Electrical and Electronic Equipment 

 

This appliance is  marked according  to  the  European 1000VAC Directive  on 
Waste  Electrical  and  Electronic  Equipment  (2002/96/EC)  and  further 
amendments. By ensuring this product is disposed of correctly, you will help 

to  prevent  potential  negative  consequences  for  the  environment  and  human  health, 
which could otherwise be caused by inappropriate waste handling of this product. 
The  symbol  on  the  product,  or  the  documents  accompanying  the  product,  indicates 
that this appliance  may  not be treated as  household  waste.  It  shall be  handed  over to 
the  applicable  collection  point  for  used  up  electrical  and  electronic  equipment  for 
recycling  purpose.  For  more  information  about  recycling  of  this  product,  please 
contact  your  local  authorities,  your  household  waste  disposal  service  or  the  shop 
where you purchased the product. 
 
 

RoHS Directive 2002/95/EC 

Out of concern for human health protection and friendly environment, we 
assure  that  our  products  falling  under  RoHS  Directive  regulations, 
regarding  the  restriction  of  the  use  of  hazardous  substances  in  electrical 
and  electronic  equipment,  have  been  designed  and  manufactured  in 
compliance  with  the  above  mentioned  regulations.  Simultaneously,  we 

claim  that  our  products  have  been  tested  and  do  not  contain  hazardous  substances 
whose  exceeding  limits  could  have  negative  impact  on  human  health  or  natural 
environment. 
 

Information 

The device, as a part of professional CCTV system used for surveillance and control, 
is  not  designed  for  self  installation  in  households  by  individuals  without  technical 
knowledge. 
The manufacturer is not responsible for defects and damages that result from improper 
or inconsistent with user’s manual installation of the device in the system. 

Summary of Contents for NVG-031TLIB

Page 1: ...NVG 031TLIB user s manual ...

Page 2: ...oduct indicates that this appliance may not be treated as household waste It shall be handed over to the applicable collection point for used up electrical and electronic equipment for recycling purpose For more information about recycling of this product please contact your local authorities your household waste disposal service or the shop where you purchased the product RoHS Directive 2002 95 E...

Page 3: ...NSIBILITY FOR THE RESULTS OF SUCH AN ACTION IMPORTANT SAFEGUARDS AND WARNINGS 1 Prior to undertaking any action please consult the following manual and read all the safety and operating instructions before starting the device 2 Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary 3 All the safety precautions referred to in this manual...

Page 4: ...ARACTERISTIC Ground loop isolator for video transmission via coaxial twisted pair video transmission Passive device which does not require the power supply Prevents video signal reduction resulting from ground loops Operates together with passive and active converters 3 SPECIFICATION FOREWORD INFORMATION Insertion Loss 0 5 dB Transmission Distance Up to 300 m Frequency 0 3 dB for 10MHz Input Resis...

Page 5: ... 1st video signal processing or displaying device Video ground loop isolators allow to separate two different mass potential circuits in order to prevent ground loops and video signal reduction Different levels of mass potential may results from unbalanced load of power supply phases as well as diverse earth potential in different places Examples of installation INSTALLATION Camera CAT 5 UTP Groun...

Page 6: ...031TLIB User s Manual version 1 2 All rights reserved AAT Holding sp z o o 6 2013 08 22 PR AN AAT Holding sp z o o ul Puławska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com ...

Page 7: ...NVG 031TLIB instrukcja obsługi ...

Page 8: ...Urządzenie należy oddać do odpowiedniego punktu utylizacji odpadów w celu recyklingu Aby uzyskać dodatkowe informacje dotyczące recyklingu niniejszego produktu należy skontaktować się z przedstawicielem władz lokalnych dostawcą usług utylizacji odpadów lub sklepem gdzie nabyto produkt Dyrektywa RoHS 2002 95 EC Informacja dla użytkowników dotycząca ograniczenia użycia substancji niebezpiecznych w s...

Page 9: ...nia się do zawartych w niej treści 3 Należy skrupulatnie przestrzegać wymogów bezpieczeństwa opisanych w instrukcji gdyż mają one bezpośredni wpływ na bezpieczeństwo użytkowników i trwałość oraz niezawodność urządzenia 4 Wszystkie czynności wykonywane przez instalatorów i użytkowników muszą być realizowane zgodnie z opisem zawartym w instrukcji 5 Nie wolno stosować żadnych dodatkowych urządzeń lub...

Page 10: ...torze transmisji wizji po skrętce Urządzenie pasywne nie wymaga zasilania Zapobiega degradacji sygnału wizyjnego w wyniku oddziaływania pętli prądowych Współpracuje z pasywnymi i aktywnymi konwerterami 3 DANE TECHNICZNE INFORMACJE WSTĘPNE Tłumienność wtrąceniowa 0 5 dB Odległość transmisji do 300 m Charakterystyka częstotliwościowa 0 3 dB dla 10MHz Rezystancja wejściowa 75 Ohm Rezystancja wyjściow...

Page 11: ... obróbki lub zobrazowania sygnału wizyjnego Separatory elektroniczne pozwalają rozdzielić obwody o różnych potencjałach masy i tym samym zapobiegają powstawaniu pętli prądowych i degradacji sygnału wideo Różne poziomy potencjału masy mogą wynikać z niezrównoważonego obciążenia faz zasilania jak i różnych potencjałów ziemi w różnych punktach Schemat przykładowej instalacji INSTALACJA Kamera skrętka...

Page 12: ...LIB instrukcja obsługi wer 1 2 Wszelkie prawa zastrzeżone AAT Holding sp z o o 6 2013 08 22 PR AN AAT Holding sp z o o ul Puławska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com ...

Reviews: