background image

TagTemp-S 

NOVUS AUTOMATION 

4/12

 

 

 

Fig. 02

 – Initial Screen of the Application  

 

Fig. 03

 – NFC Communication 

After starting the application (see 

Fig. 02

), simply bring the 

smartphone closer to the 

TagTemp-S

 (see 

Fig. 03

) until the data in 

the register has been transferred. This typically takes a few seconds, 

but depends on the smartphone model used. 
The application has six screens: 

1.

 

Device Status 

2.

 

Device Configuration 

3.

 

Events and Occurrences 

4.

 

Data Charts 

5.

 

Preferences 

6.

 

Download 

5.2.1

 

Device Status Screen

 

 

 

Fig. 04 

– Device Status Screen 

 

Last  recorded  value

: Shows the value of the last recorded 

made by 

TagTemp-S

. It does not always equal the current 

temperature.

 

 

Loggings

: Indicates basic information about 

TagTemp-S

.

 

Log interval

: Indicates the value defined of the interval 

between each acquisition.

 

  Loggings

:  Indicates the number of records made by 

TagTemp-S

.

 

  Logging state

: Indicates hether the log is running, stopped or

 

waiting for loggings to start

 – Start Delay.

 

 

  Memory  usage

: Indicates the memory usage mode (full or 

circular).

 

 

Battery

Indicates the status of the battery charge.

 

  Good

: Perfect to use.

 

  Medium

: Significant discharge is already detected. It should be 

monitored.

 

  Low

: The battery is discharged. In this case, you will not be able 

to send new settings or continue recording the temperature. 

 

Device Info

Indicates some specific information of 

TagTemp-S

  Device tag

: Identification the name chosen by the user. 

  Model

TagTemp-S

.

 

  Serial Number

: Serial number engraved factory.

 

  UID

: Unique Identification Number. Useful for tracking applications.

 

  Firmware version

: Device firmware version number. 

Summary of Contents for TagTemp-S

Page 1: ...NOVUS AUTOMATION 1 12 TagTemp S INSTRUCTION MANUAL V1 0x A ...

Page 2: ...ion tag Another way is to use the blister hole to attach the transmitter 3 TECHNICAL FEATURES Operating Temperature 30 C to 60 C Storage Temperature From 30 C to 65 C Measuring Range Temperature 30 0 C to 60 0 C Accuracy of Measurement 1 C max over the full measuring range Note The user can correct the measurement error in the Offset parameter using the configuration software Measurement Resolutio...

Page 3: ...ted on the front of the product can be used to start or stop data logging according to the settings To give the command to start or stop logs press this button until the LED turns on and then release it before it goes out If the LED goes off before releasing the button the command will not be validated and the button will be disabled for 30 seconds This is a protective measure to prevent accidenta...

Page 4: ...on about TagTemp S Log interval Indicates the value defined of the interval between each acquisition Loggings Indicates the number of records made by TagTemp S Logging state Indicates hether the log is running stopped or waiting for loggings to start Start Delay Memory usage Indicates the memory usage mode full or circular Battery Indicates the status of the battery charge Good Perfect to use Medi...

Page 5: ... option you can start logging data by pressing the device button Stop loggings by button When you enable this option you can stop logging by pressing the device button Enable circular memory When this option is enabled when the memory is complete the recording will continue overwriting the oldest records Use Fahrenheit degrees When this option is enabled the temperature unit of Celsius default is ...

Page 6: ...sured value was below the specified lower limit for the range First occurrence The time of the first event the measured value was below the minimum limit Last occurrence The time from the last event the measured value was below the minimum limit Total logs within occurrences Number of acquisitions below the minimum range limit Average temperature within occurrences Average value of temperatures be...

Page 7: ...the last 2000 To select a graph display range the Chart range option can be used 5 2 4 1 Data Chart Options Screen When the user selects the icon in the upper right of the screen the chart options will appear Fig 14 Data Chart Options Screen 1 Share By pressing the icon the user can share the obtained data using the applications already installed in the smartphone or through the option of publishi...

Page 8: ...atible with NXperience nxd so that the data can be read and displayed by this application Initial Screen Selection Allows the user to select the startup screen after reading the data from the device NOVUS Cloud Authentication Hire an account in the NOVUS Cloud to store the TagTemp S data Enter the login credentials in the Username and Password fields to send the data Export Automatically If this o...

Page 9: ...sage will be displayed Fig 24 Reading Device Screen Stop logging This option stops data logging and is read allowing the device to be configured Show Only By choosing this option the user can only view the device s settings Functions such as saving settings changing the password or setting the device to idle mode will be disabled After reading the device the configuration screen is shown below in ...

Page 10: ...de for the connected device Save File This option allows the user to save the configuration settings made to a file so it can be reused to configure other devices Security This option allows the user to create change or delete a password The password must be four digits long Fig 29 shows the definition and password change screen Fig 29 Definition and Password Change Screen Idle Mode This option pl...

Page 11: ...files for viewing customizing preparing reports or other functions Fig 36 Downloading the Device Logs 6 4 2 Viewing Downloaded Data After the transfer of the records the data downloaded are presented graphically as shown in the images below Fig 37 Viewing Downloading Data 6 4 1 Sharing and Processing Data After completing the download a screen will be displayed with the downloaded data and these a...

Page 12: ... 7 Zoom 8 Properties 9 Report Export Logs 10 NOVUS Cloud 11 Exit 6 5 Exporting and Creating Reports Using the NXperience the user can export the downloaded data to various file formats or create reports from the available models These two features are accessed by clicking the Report Export Logs button in the function menu Export to Other Formats Selecting this option from the Model options a secon...