background image

TagTemp-S 

NOVUS AUTOMATION 

8/12

 

3.

 

Graph Interval

 

:  This option allows the user  to select the 

range of values that will be displayed in the chart. This range can 

include up to 2000 records. 

  View options

: Option to choose the start and end date for the 

range of the records to see the data downloaded. 

 

Fig. 17

 – View Options Screen 

5.2.4.2

 

Preference Settings Screen

 

 

 

Fig. 18

 – Preferences Settings screen 

 

Default Share Options

: The user can set the display preferences 

according to the data he want to receive using the share function.

 

  Keep Downloaded Data in Smartphone

: Keeps files, previously 

selected in the sharing options, in a folder called 

LogChart-NFC

 

in the internal memory of the smartphone.

 

  Export  Logs  (.CSV)

: Shares a file with .csv  extension with all 

records from the last download.

 

  Export Configuration (.CFG)

: Shares a text file with 

TagTemp-S

 

settings data, useful for backup and future reference. The shared 

configuration is the one that is read from the device, the 

subsequent changes will not be considered.

 

  Export to NXperience (.NXD)

: Shares a file with the downloaded 

data in a format compatible with 

NXperience

 (.nxd), so that the 

data can be read and displayed by this application. 

 

Initial  Screen Selection

: Allows the user  to select the startup 

screen after reading the data from the device.

 

 

NOVUS Cloud Authentication

: Hire an account in the 

NOVUS

 

Cloud

 to store the 

TagTemp-S

 data. Enter the login credentials 

in the "Username" and "Password" fields to send the data.

 

 

Export  Automatically

: If this option is selected, whenever a 

device's data is downloaded, the application will try to send them 

automatically to 

NOVUS Cloud

 

FTP Authentication

With an active 

FTP

 server, enter the host 

address, user credentials, and connection port for this server. 

Automatically Export: With this option checked, whenever a data 

download of a 

TagTemp

 is performed, the application will attempt 

to automatically send the data to the 

FTP

 server. 

5.2.5

 

Manage Downloads Screen 

 

Fig. 19

 – Manage Downloads screen 

 

 

Fig. 20 

– Share Screen 

This screen allows the user to delete and share the data downloaded 

previously. A list of downloaded data is displayed, and the user can 

select a file to share or delete. 
To share a selected item, the user  only has  to press the 

corresponding button in the upper right of the screen. 
To delete an item, press and hold the respective item until the delete 

confirmation dialog appears. 

Summary of Contents for TagTemp-S

Page 1: ...NOVUS AUTOMATION 1 12 TagTemp S INSTRUCTION MANUAL V1 0x A ...

Page 2: ...ion tag Another way is to use the blister hole to attach the transmitter 3 TECHNICAL FEATURES Operating Temperature 30 C to 60 C Storage Temperature From 30 C to 65 C Measuring Range Temperature 30 0 C to 60 0 C Accuracy of Measurement 1 C max over the full measuring range Note The user can correct the measurement error in the Offset parameter using the configuration software Measurement Resolutio...

Page 3: ...ted on the front of the product can be used to start or stop data logging according to the settings To give the command to start or stop logs press this button until the LED turns on and then release it before it goes out If the LED goes off before releasing the button the command will not be validated and the button will be disabled for 30 seconds This is a protective measure to prevent accidenta...

Page 4: ...on about TagTemp S Log interval Indicates the value defined of the interval between each acquisition Loggings Indicates the number of records made by TagTemp S Logging state Indicates hether the log is running stopped or waiting for loggings to start Start Delay Memory usage Indicates the memory usage mode full or circular Battery Indicates the status of the battery charge Good Perfect to use Medi...

Page 5: ... option you can start logging data by pressing the device button Stop loggings by button When you enable this option you can stop logging by pressing the device button Enable circular memory When this option is enabled when the memory is complete the recording will continue overwriting the oldest records Use Fahrenheit degrees When this option is enabled the temperature unit of Celsius default is ...

Page 6: ...sured value was below the specified lower limit for the range First occurrence The time of the first event the measured value was below the minimum limit Last occurrence The time from the last event the measured value was below the minimum limit Total logs within occurrences Number of acquisitions below the minimum range limit Average temperature within occurrences Average value of temperatures be...

Page 7: ...the last 2000 To select a graph display range the Chart range option can be used 5 2 4 1 Data Chart Options Screen When the user selects the icon in the upper right of the screen the chart options will appear Fig 14 Data Chart Options Screen 1 Share By pressing the icon the user can share the obtained data using the applications already installed in the smartphone or through the option of publishi...

Page 8: ...atible with NXperience nxd so that the data can be read and displayed by this application Initial Screen Selection Allows the user to select the startup screen after reading the data from the device NOVUS Cloud Authentication Hire an account in the NOVUS Cloud to store the TagTemp S data Enter the login credentials in the Username and Password fields to send the data Export Automatically If this o...

Page 9: ...sage will be displayed Fig 24 Reading Device Screen Stop logging This option stops data logging and is read allowing the device to be configured Show Only By choosing this option the user can only view the device s settings Functions such as saving settings changing the password or setting the device to idle mode will be disabled After reading the device the configuration screen is shown below in ...

Page 10: ...de for the connected device Save File This option allows the user to save the configuration settings made to a file so it can be reused to configure other devices Security This option allows the user to create change or delete a password The password must be four digits long Fig 29 shows the definition and password change screen Fig 29 Definition and Password Change Screen Idle Mode This option pl...

Page 11: ...files for viewing customizing preparing reports or other functions Fig 36 Downloading the Device Logs 6 4 2 Viewing Downloaded Data After the transfer of the records the data downloaded are presented graphically as shown in the images below Fig 37 Viewing Downloading Data 6 4 1 Sharing and Processing Data After completing the download a screen will be displayed with the downloaded data and these a...

Page 12: ... 7 Zoom 8 Properties 9 Report Export Logs 10 NOVUS Cloud 11 Exit 6 5 Exporting and Creating Reports Using the NXperience the user can export the downloaded data to various file formats or create reports from the available models These two features are accessed by clicking the Report Export Logs button in the function menu Export to Other Formats Selecting this option from the Model options a secon...