Display
Display
Designation
Function
0
Zero
The heating zone is activated
1…9
Power level
Selection of the cooking level
U
Pan Detection
No pan or inadequate pan
A
Heat accelerator
Automatic cooking
E
Error message
Electronic failure
H
Residual heat
The heating zone is hot
P
Booster
The boosted power is activated
U
Keep Warm
Maintain automatically at 70°C.
II
Pause
The pause is activated
Ventilation
The cooling system is fully automatic. The cooling fan starts with a low speed when the
calories brought out by the electronic system reach a certain level. The ventilation starts his
high speed when the hob is intensively used. The cooling fan reduces his speed and stops
automatically when the electronic circuit is cooled enough.
STARTING-UP AND APPLIANCE MANAGEMENT
Before the first use
Clean your hob with a damp cloth, and then dry the surface thoroughly. Do not use detergent
which risks causing blue-tinted colour on the glass surface.
Induction principle
An induction coil is located under each heating zone. When it is engaged, it produces a
variable electromagnetic field which produces inductive currents in the ferromagnetic bottom
plate of the pan. The result is a heating-up of the pan located on the heating zone.
Of course the pan has to be adapted:
All ferromagnetics pans are recommended (please verify it thanks a little magnet): cast
iron and steel pans, enamelled pans, stainless-steel pans with ferromagnetic
bottoms…
Are excluded : cupper, pure stainless-steel, aluminium, glass, wood, ceramic,
stoneware,…
The induction heating zone adapts automatically the size of the pan. With a too small
diameter the pans doesn’t work. This diameter is varying in function of the heating zone
diameter.If the pan is not adapted to the induction hob the display will show [ U ].
Starting-up
Start-up/ switch off the hob
Action
Control panel
Display
To start:
Touch the key [ 0/I ]
[ 0 ]
To stop:
Touch the key [ 0/I ]
nothing or [ H ]
Summary of Contents for 1706