background image

4

IMPORTANT SAFETY INSTRUCTIONS, 

continued

PROPER PLACEMENT OF YOUR HOT TUB

POWER INSTALLATION INSTRUCTIONS

WARNING: When using this electrical equipment, basic safety precautions 

should always be followed, including the following:

      • A green colored terminal or a terminal marked G, GR, Ground,

        Grounding, or with the          symbol is located inside the supply terminal   

        box or compartment. To reduce the risk of electric shock, this terminal  

        must be connected to the grounding means provided in the electric  

        supply service panel with a continuous copper wire equivalent in size to  

        the circuit conductors supplying this equipment.

      • At least two lugs marked “BONDING LUGS” are provided on the external  

        surface or on the inside of the supply terminal box or compartment. To  

        reduce the risk of electric shock, connect the local common bonding grid    

        in the area of the hot tub or spa to these terminals with an insulated or  

        bare copper conductor not smaller than No. 6 AWG (13 mm2).

      • All field-installed metal components such as rails, ladders, drains or other  

        similar hardware within 1.5 m(5 ft) of the spa or hot tub shall be bonded  

        to the equipment grounding bus with copper conductors not smaller than  

        No. 6 AWG (13 mm2).

It is extremely important that the base on which the hot tub is placed is 

smooth, level, and can uniformly support the complete weight without settling 

or shifting. If these requirements are not met, possible damage to your cabinet 

or tub shell may result. Damage caused by improper support is not covered 

under warranty. It is the responsibility of the hot tub owner to meet these 

requirements and to assure the integrity of the hot tub support at all times.

   

230V/240V Service

NO PLUG-IN CONNECTIONS OR EXTENSION CORDS ARE TO BE         

USED IN CONJUNCTION WITH THE OPERATION OF THIS TUB. All 

wiring must be permanently connected (hard wired) to the equipment 

pack. Power supply that is not in accordance with these instructions will 

void warranty.

This tub requires that the power supply be on a dedicated circuit with no 

other electrical appliances or lights sharing the circuit that is providing 

power to the hot tub.

Do not use aluminum wiring. ALL WIRING MUST BE COPPER.

A suitable ground fault circuit interrupter (GFCI) as required by the local 

building/electrical inspection authority, must be included in the electrical 

circuit supplied to the hot tub.

Proper wire size must be used in accordance to the local building/

electrical inspection authority.

All wires must be securely hooked up or damage could result. 

TIGHTEN SECURELY!

   

120V Service

This tub requires that the power supply be on a dedicated

circuit with no other electrical appliances or lights sharing the

circuit that is providing power to the hot tub.

Do not use aluminum wiring. ALL WIRING MUST BE COPPER.

A suitable ground fault circuit interrupter (GFCI) as required by

the local building/electrical inspection authority, must be

included in the electrical circuit supplied to the hot tub.

Proper wire size must be used in accordance by the local

building/electrical inspection authority.

SAVE THESE INSTRUCTIONS.

WARNING: Prolonged immersion in hot water may induce hyperthermia. 

Hyperthermia occurs when the internal temperature of the body reaches a 

level several degrees above the normal body temperature of 98.6°F (37°C). 

The symptoms of hyperthermia include drowsiness, lethargy, and an increase 

in the internal temperature of the body. The effects of hyperthermia are:

     1. Unawareness of impending hazard;

     2. Failure to perceive heat;

     3. Failure to recognize the need to exit the hot tub;

     4. Physical inability to exit the hot tub;

     5. Fetal damage in pregnant women;

     6. Unconsciousness and danger of drowning.

WARNING: THE USE OF ALCOHOL OR DRUGS CAN GREATLY

INCREASE THE RISK OF FATAL HYPERTHERMIA IN HOT TUBS OR SPAS.

CAUTION: MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH

MANUFACTURER’S INSTRUCTION.

CAUTION: TEST THE GROUND FAULT CIRCUIT INTERRUPTER

BEFORE EACH USE OF THE SPA.

We recommend a reinforced poured concrete slab that has a minimum 

thickness of 4 inches (10cm). If a wood deck is used, construction must 

comply with all local building codes.

Proper drainage around the hot tub is necessary to allow overflow, rain and 

other casual water to drain away from the hot tub so the equipment area does 

not get flooded and cause problems. Failure to do so will void warranty.

Important Notice:

 The electrical installation of this tub must meet the requirements of all applicable country, state and local 

codes. The electrical installation must be performed by a qualified electrician and be approved by the local building/electrical 

inspection authority.

WARNING: DO NOT TURN ON POWER UNTIL TUB IS FILLED COMPLETELY WITH WATER!

1.

2.

3.

4.

5.

6.

1.

2.

3.

4.

Cord Connection Option

The cord connection option is only available for 120V operation on the models 

rated 12/32 A. Only the manufacturer recommended power cord and GFCI 

should be used for cord connected installations. Plug the cord into a 120V 

receptacle. 

Summary of Contents for 110 Crown

Page 1: ...10 Stella 110 Retreat 110 Encore Warrior XL Crown Crown XL Escape MS Escape R MS Encore MS Jubilee MS Escape SE Escape R SE Encore SE Encore LS Rendezvous LS 110 Sport 110 Warrior XL 110 D Amour 110 C...

Page 2: ...Rev 11 2017 IMPORTANT SAFETY INSTRUCTIONS PROPER PLACEMENT OF YOUR HOT TUB POWER INSTALLATION INSTRUCTIONS POWER REQUIREMENTS START UP INSTRUCTIONS OPERATING INSTRUCTIONS CEDAR CABINET PERMAWOOD PERM...

Page 3: ...abetes or any condition requiring medical treatment should consult a physician before using a hot tub Persons using medication should consult a physician before using a hot tub since some medication m...

Page 4: ...d in accordance to the local building electrical inspection authority All wires must be securely hooked up or damage could result TIGHTEN SECURELY 120V Service This tub requires that the power supply...

Page 5: ...any other equipment DO NOT USE EXTENSION CORDS OF ANY KIND Amp Volts of wires 230V 16A 3 230V 32A 3 Tub Model Europe 50Hz Only Omni Impulse Impulse DP Crown II Warrior XL Crown Crown XL Bella MS D Amo...

Page 6: ...bs during the winter months Topside Control Pad Your hot tub is equipped with an electronic topside control pad The topside control pad wil allow you to control the speed of the pump the light and the...

Page 7: ...INTERIZING YOUR HOT TUB continued Drain your tub Inside the equipment room there is a spigot for a garden hose It is attached to a clear vinyl hose near the main control box With the wet vac remove an...

Page 8: ...ce pH total alkalinity not in balance Damaged or dirty filter Addition of incompatible chemicals Low chlorine level Buildup of oils soap foreign matter Copper or iron metals in Hot Tub due to water su...

Page 9: ......

Page 10: ......

Page 11: ...r up After the pump has been running for 2 minutes the current water temperature will be displayed DO NOT ENTER THE WATER Remove the spa cover and allow water to cool Once the heater has cooled reset...

Page 12: ...o durante l uso di vasca caldo potrebbe condurre all inconscienza con la possibilit di annegare Le persone obese e le persone con una storia di malattia di cuore basso o l ipertensione i problemi di s...

Page 13: ...rmia sono 1 L Unawareness di pericolo imminente 2 Il fallimento di percepire il calore 3 Il fallimento di riconoscere il bisogno per uscire la vasca calda 4 L inabilit fisica di uscire la vasca calda...

Page 14: ...ovo e collegare la Vasca ad una massa a terra UN nuovo GFCI deve essere utilizzata per la vasca idromassaggio Non usare un interruttore GFCI come la sua condizione sconosciuto In tutti i sistemi la va...

Page 15: ...DEL RIVESTIMENTO DEL FILTRO DELLA VASCA INTERNA E DELLA COPERTURA Cedro rosso Vista l esigenza di tutti i prodotti in legno il trattamento dell esterno del vostro mobile in legno richiede un programm...

Page 16: ...er modello Generatore di ozono opzionale Accessori richiesti Liquido antigelo non tossico Un aspiratore liquidi Un secchio o annaffiatoio 1 o 2 sacchetti di plastica Tempo approssimativo 2 ore Modo d...

Page 17: ...ssivo l interno vasca verificare l acqua e regolare pH e cloro se necessario Aggiungere un prodotto chimico anticalcareo Aggiungere un chiarificatore dell acqua mettere in movimento l acqua per almeno...

Page 18: ......

Page 19: ...d acqua rilevato nel riscaldatore Inadequate water detected in heater Displays on third occurrence of message Spa is shut down Ghiaccio stata rilevata una condizione di possibile congelamento Il quadr...

Page 20: ...de temp rature d eau varie La consommation d alcool de drogues ou de m dicaments avant ou pendant l utilisation d un spa peut causer l vanouissement et comporte donc un risque de noyade Les personnes...

Page 21: ...ERMIE MORTELLE DANS UN SPA ATTENTION MAINTENIR LA COMPOSITION CHIMIQUE DE L EAU CONFORM MENT AUX INSTRUCTIONS DU FABRICANT ATTENTION FAIRE L ESSAI DU DISJONCTEUR DE FUITE LA TERRE AVANT CHAQUE UTILISA...

Page 22: ...disponible pour votre cuve de relaxation Il est important d utiliser un nouveau disjoncteur avec mise la terre int gr e GFCI Sur tous les syst mes votre cuve de relaxation doit tre raccord e un circui...

Page 23: ...EV TEMENT EXT RIEUR C dre rouge de l ouest Tel que l exige tout produit de bois le maintien de la beaut de votre meuble requiert un programme rigoureux de traitement du bois entourant votre cuve de re...

Page 24: ...s petites fuites partout dans la zone d quipement Si vous n tes pas certain de savoir o sont situ s les joints d tanch it veuillez communiquer votre concessionnaire pour en savoir d avantage Si le rem...

Page 25: ...Ajouter un produit chimique pour contr ler les taches et les d p ts calcaires Ajouter un clarificateur d eau Faire circuler pendant au moins 30 minutes Lorsque l eau s est claircie nettoyer le bo tie...

Page 26: ......

Page 27: ......

Page 28: ...tirer la couverture du spa et laisser l eau refroidir Une fois que le chauffe eau a refroidi r initialiser en appuyant sur une touche quelconque Si le spa ne se r initialise pas le mettre hors tension...

Page 29: ...ilit in modo da proteggere la salute umana e l ambiente WEEE Directif 2012 19 EU Le marquage sur le produit les accessoires ou la documentation indique que le produit et ses accessoires lectroniques n...

Page 30: ...let Volts DIMENSIONI E CAPACIT 213 4 cm X 182 9 cm 86 4 cm 776 Litres approx Approx 159 6 kg 14 110V 60hz only North American Only 213 4 cm X 182 9 cm 86 4 cm 776 L circa Circa kg 159 6 14 110V 60hz o...

Page 31: ...CIT 177 8 cm X 203 2 cm 86 4 cm 946 Litres approx Approx 179 2 kg 13 110V 60hz only North American Only 177 8 cm X 203 2 cm 86 4 cm 946 L circa Circa kg 179 2 13 110V 60hz only North American Only 70...

Page 32: ...otale getti Volts Dimensions Profondeur Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 199 4 cm 88 9 cm 1060 Litres approx Approx 152 kg 21 110V 220V 230V Europe 199 4 cm 88 9 cm 1060 L cir...

Page 33: ...eso a vuoto Totale getti Volts Dimensions Profondeur Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 213 4 cm 88 9 cm 104 Litres approx Approx 156 kg 22 110 220V 230V Europe 213 4 cm 88 9 cm...

Page 34: ...s Profondeur Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 213 4 cm X 182 9 cm 86 4 cm 776 Litres approx Approx 159 6 kg 26 110V 220V 230V Europe 213 4 cm X 182 9 cm 86 4 cm 776 L circa Ci...

Page 35: ...r Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 203 2 cm X 208 3 cm 88 9 cm 1136 Litres approx Approx 204 1 kg 22 110V 220V 230V Europe 203 2 cm X 208 3 cm 88 9 cm 1136 L circa Circa kg 20...

Page 36: ...r Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 213 4 cm X 182 9 cm 86 4 cm 776 Litres approx Approx 159 6 kg 26 220V Only 230V Europe 213 4 cm X 182 9 cm 86 4 cm 776 L circa Circa kg 159...

Page 37: ...eur Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 203 2 cm X 208 3 cm 88 9 cm 1136 Litres approx Approx 215 kg 30 220V Only 230V Europe 203 2 cm X 208 3 cm 88 9 cm 1136 L circa Circa kg 21...

Page 38: ...ondeur Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 203 2 cm X 208 3 cm 88 9 cm 1136 Litres approx Approx 245 kg 45 220V Only 230V Europe 203 2 cm X 208 3 cm 88 9 cm 1136 L circa Circa kg...

Page 39: ...Volts Dimensions Profondeur Capacit Poids sec Jets complet Volts 84 X 96 36 Approx 373 Gal Approx 625 lbs 49 220V Only 230V Europe 213 4 cm X 243 8 cm 91 4 cm 1412 L circa Circa kg 283 5 49 220V Only...

Page 40: ...c Jets complet Volts DIMENSIONI E CAPACIT 213 4 cm X 213 4 cm 88 9 cm 1230 Litres approx Approx 213 kg 30 110V 220V 230V Europe 213 4 cm X 213 4 cm 88 9 cm 1230 L circa Circa kg 213 30 110V 220V 230V...

Page 41: ...olts Dimensions Profondeur Capacit Poids sec Jets complet Volts DIMENSIONI E CAPACIT 213 4 cm X 213 4 cm 88 9 cm 1230 Litres approx Approx 257 kg 46 220V Only 230V Europe 213 4 cm X 213 4 cm 88 9 cm 1...

Page 42: ...HOT TUB...

Page 43: ......

Page 44: ..._______________________________________________________________ DEALER INFORMATION Name _________________________________________ Installation Location _________________________________________ Addres...

Reviews: