1. Safety Regulations 

 

VERY IMPORTANT

:

 Instruments and components supplied by npi electronic are NOT 

intended for clinical use or medical purposes (e.g. for diagnosis or treatment of humans), 
or for any other life-supporting system. npi electronic disclaims any warranties for such 
purpose. Equipment supplied by npi electronic must be operated only by selected, 
trained and adequately instructed personnel. For details please consult the GENERAL 
TERMS OF DELIVERY AND CONDITIONS OF BUSINESS of npi electronic, D-71732 
Tamm, Germany.

 

 
1)  GENERAL: This system is designed for use in scientific laboratories and must be 

operated only by trained staff. General safety regulations for operating electrical devices 
should be followed. 

 
2)  AC MAINS CONNECTION: While working with the npi systems, always adhere to the 

appropriate safety measures for handling electronic devices. Before using any device 
please read manuals and instructions carefully. 
The device is to be operated only at 115/230 Volt 60/50 Hz AC. Please check for 
appropriate line voltage before connecting any system to mains. 
Always use a three-wire line cord and a mains power-plug with a protection contact 
connected to ground (protective earth).  
Before opening the cabinet, unplug the instrument. 
Unplug the instrument when replacing the fuse or changing line voltage. Replace fuse 
only with an appropriate specified type. 

 
3)  STATIC ELECTRICITY: Electronic equipment is sensitive to static discharges. Some 

devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can 
be damaged by electrostatic charge and must therefore be handled with care. Electrostatic 
discharge can be avoided by touching a grounded metal surface when changing or 
adjusting sensors. 

Always turn power off when adding or removing modules, 

connecting or disconnecting sensors, headstages or other components from the 
instrument or 19” cabinet.

 

 
4)  TEMPERATURE DRIFT / WARM-UP TIME: All analog electronic systems are 

sensitive to temperature changes. Therefore, all electronic instruments containing analog 
circuits should be used only in a warmed-up condition (i.e. after internal temperature has 
reached steady-state values). In most cases a warm-up period of 20-30 minutes is 
sufficient. 

 
5)  HANDLING: Please protect the device from moisture, heat, radiation and corrosive 

chemicals. 

 

Summary of Contents for EXT-10C

Page 1: ...ION FOR THE EXT 10C EXTRACELLULAR AMPLIFIER MODULE FOR EPMS SYSTEMS VERSION 1 5 npi 2005 npi electronic GmbH Hauptstrasse 96 D 71732 Tamm Germany Phone 49 0 7141 601534 Fax 49 0 7141 601266 support np...

Page 2: ...ents 1 Safety Regulations 3 2 EPMS 07 Modular Plug In System 4 2 1 Components of the EPMS 07 Housing 4 2 2 General System Description Operation 4 2 3 System Grounding 5 2 4 Technical Data 5 3 EXT 10C...

Page 3: ...only at 115 230 Volt 60 50 Hz AC Please check for appropriate line voltage before connecting any system to mains Always use a three wire line cord and a mains power plug with a protection contact conn...

Page 4: ...e plug in units are connected to power by a bus at the rear panel The plug in units must be kept in position by four screws M 2 5 x 10 The screws are important not only for mechanical stability but al...

Page 5: ...internal ground is used on the BNC connectors or GROUND plugs of the modules that are inserted into the EPMS 07 housing The internal ground and mains ground protective earth can be connected by a wire...

Page 6: ...dstage with a holding bar The EXT 10C has a differential input with high input resistance for minimizing noise and the incoming signal can be compensated for offset and capacity of the microelectrode...

Page 7: ...d by the name in uppercase letters written on the front panel and the type of the element in lowercase letters Then a short description of the element is given 1 HEADSTAGE connector The HEADSTAGE cabl...

Page 8: ...l cancellation of the OFFSET 6 OVER OVER LEDs LEDs that indicate if the amplifier 10 below it s positive or negative limit 10 V The linear range of the amplifier is 12 V 7 OFFSET potentiometer 10 turn...

Page 9: ...l input that minimizes noise pick up Differential means that the signal for the amplifier is the difference between the positive PEL and negative REF input of the headstage This results in canceling o...

Page 10: ..._________________________________________________________ Figure 4 headstage connections A differential measurement B single ended measurement _________________________________________________________...

Page 11: ...ter maze performance exploratory activity inhibitory avoidance and hippocampal plasticity in aged superior and inferior learners Eur J Neurosci 16 2175 2185 Kettenmann H Grantyn R eds 1992 Practical E...

Page 12: ...t range 12 V into 1 k 1 V into 50 load Output AC selectable gain x100 x1k x10k Output range 12 V into 1 k 1 V into 50 load corner frequency 10 Hz Offset compensation 10 turn potentiometer 100 mV Poten...

Reviews: