1. Safety Regulations 

 

VERY IMPORTANT

:

 Instruments and components supplied by npi electronic are NOT 

intended for clinical use or medical purposes (e.g. for diagnosis or treatment of humans), 
or for any other life-supporting system. npi electronic disclaims any warranties for such 
purpose. Equipment supplied by npi electronic must be operated only by selected, 
trained and adequately instructed personnel. For details please consult the GENERAL 
TERMS OF DELIVERY AND CONDITIONS OF BUSINESS of npi electronic, D-71732 
Tamm, Germany.

 

 
1)

 

GENERAL: This system is designed for use in scientific laboratories and must be 
operated by trained staff only. General safety regulations for operating electrical devices 
should be followed. 

 
2)

 

AC MAINS CONNECTION: While working with the npi systems, always adhere to the 
appropriate safety measures for handling electronic devices. Before using any device 
please read manuals and instructions carefully. 
The device is to be operated only at 115/230 Volt 60/50 Hz AC. Please check for 
appropriate line voltage before connecting any system to mains. 
Always use a three-wire line cord and a mains power-plug with a protection contact 
connected to ground (protective earth).  
Before opening the cabinet, unplug the instrument. 
Unplug the instrument when replacing the fuse or changing line voltage. Replace fuse 
only with an appropriate specified type. 

 
3)

 

STATIC ELECTRICITY: Electronic equipment is sensitive to static discharges. Some 
devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can 
be damaged by electrostatic charge and must therefore be handled with care. Electrostatic 
discharge can be avoided by touching a grounded metal surface when changing or 
adjusting sensors. 

Always turn power off when adding or removing modules, 

connecting or disconnecting sensors, headstages or other components from the 
instrument or 19” cabinet.

 

 
4)

 

TEMPERATURE DRIFT / WARM-UP TIME: All analog electronic systems are 
sensitive to temperature changes. Therefore, all electronic instruments containing analog 
circuits should be used only in a warmed-up condition (i.e. after internal temperature has 
reached steady-state values). In most cases a warm-up period of 20-30 minutes is 
sufficient. 

 
5)

 

HANDLING: Please protect the device from moisture, heat, radiation and corrosive 
chemicals. 

 

Summary of Contents for R/I-T1DX

Page 1: ...TION FOR THE R I T1DX ELECTRODE RESISTANCE TEST CURRENT INJECTION VERSION 1 4 npi 2013 npi electronic GmbH Bauhofring 16 D 71732 Tamm Germany Phone 49 0 7141 9730230 Fax 49 0 7141 9730240 support npie...

Page 2: ...__________________ ___________________________________________________________________________ version 1 4 page 2 Table of Contents 1 Safety Regulations 3 2 R I T1DX Resistance Test Current Injection...

Page 3: ...is to be operated only at 115 230 Volt 60 50 Hz AC Please check for appropriate line voltage before connecting any system to mains Always use a three wire line cord and a mains power plug with a prot...

Page 4: ...sulting in a rectangular current signal at the electrode For electrode resistance test the voltage drop at the electrode caused by the current signal is measured and the electrode resistance is calcul...

Page 5: ...by 5 5 RESISTANCE CURRENT display Digital display showing the electrode resistance XX XX M range 0 01 M 10 M or the amplitude of the injected current XXX nA range 0 100 nA 6 Current nA resistance M LE...

Page 6: ...Customized auxiliary connector 3 TTL IN connector BNC connector for remote control of operation with a TTL signal As long as the signal is HI 2 5V operation electrode resistance test or current inject...

Page 7: ...itive current C is the capacitor in the amplifier headstage 3 3 pF dU dt is the change of the voltage amplitude of the triangle over time Example for frequency with fixed amplitude of the triangle 10...

Reviews: