        INST2063 – 2/19 

Maintenance 
 

 

The only maintenance required is the annual replacement of the Ionizer to ensure maximum 
effectiveness of the ionizer.  It is required to return the expired device to NRD for proper 
disposal. 

 

Calibration is not required. 

 
 
 
 
 

3.0   Trouble Shooting Guide 

 

Symptom 

Probable Cause 

Corrective Action 

 
1.

 

Static charges are not  
eliminated 

 
Ion cell may be out of date and 
need replacement. 
 
Possible oil contamination of ion 
cell. 
 
 
Ions generated are being 
recombined before they reach the 
charged surface. 

 
Call NRD for Ion Cell 
replacement. 
 
Return cell to NRD for 
evaluation.  Do not attempt to 
clean the device. 
 
Position the fan closer to the 
charged part. 
 

 
2.

 

Fan does not turn on 

 
No power. 
 
Blown fuse internal to fan. 

 
Check outlet and breakers. 
 
Check for visible damage to 
power cord.  Return fan to NRD 
for evaluation. 

 

Summary of Contents for P-2063

Page 1: ...m NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com INST2063 2 19 Instruction Manual for P 2063 Ionizer Accessories CONTENTS 1 0 Model P 2063 Ionizer Page 1 2 0 Accessories Page 2 2 1 Model 4064 Fan 2 2 Model 4070 Overhead Ionizing Fan 3 0 Troubleshooting Page 3 ...

Page 2: ...a Charged parts that are placed in close proximity to the ion cell can also be effectively neutralized without the need of air movement 1 1 Installation Operation A One common method to install the P 2063 Ionizer is by using spring clips that will snap on to the posts of the Ionizer The spring clips can be attached to a mounting base There are other methods to mounting the cell but cannot involve ...

Page 3: ...me of ionized air to reduce charge on parts The Fan is mounted on a swivel base and can be placed on a flat surface or bolted to a rigid surface 2 2 Model 4070 Alpha Staticmaster Overhead Ionizing Fan When using the Model 4070 the ideal neutralization time for the target is when it s placed 18 to 36 directly under the ionizing fan and increases as the distance increases Procedure to install a new ...

Page 4: ... the expired device to NRD for proper disposal Calibration is not required 3 0 Trouble Shooting Guide Symptom Probable Cause Corrective Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for ev...

Reviews: