2000 Cycles Maintenance Counter - Alarm
Once the operator has reached 2,000 cycles, the built in alarm will sound and the courtesy light
will flash. The alarm and lights will continue to flash until cancelled. This serves as a reminder to
the user to carry out the annual maintenance inspection and service.
To cancel the alarm do one of the following:
1. Press and button on the transmitter for 3 seconds
2. Press P button for 5 seconds (installer only)
3. Power off, then on the operator
To activate or de-activate the cycle alarm:
1. Press P button for 5 seconds, LED 1,2 & 3 are illuminated
2. Press + five times, LED 1, 2 & 3 flash
3. Press + to check the status of the alarm setting
4. Press + or - to toggle between alarm on or off.
5. Press P button to confirm setting.
LED
Status Meaning
LED1 Flashes once every 3 seconds
Alarm ON
LED 1 Flashes twice every 3 seconds
Alarm OFF
Programming 2000 Cycles Counter Alarm