12
3
S
P
+
-
Control Board Layout
Parts Lists
Control Board Wiring
- +
Transformer
plug
Motor
Plugs
LED 2
LED 3
LED 1
P
S
-
+
24v
dc B
at
ter
y B
ac
ku
p
C
our
tesy lig
ht p
lug
•
LED light connections: The Nrg Automation 1 mtr light strip can be connected to the to
terminals. 6 & 7. The LED will illuminate as a courtesy light and can also be turned on or
off using the mode 3 function on the transmitter.
•
A 24Vdc battery backup unit can be connected to the two battery terminals. The number
of operations depends on the size of the batteries. A two piece battery pack with 7 amps
(24vdc) can provide approximately 40 complete cycles. A single battery of 7 amps would
provide enough power for approximately 30 cycles.
1
2
3
4
5
6
7
8
9
Terminal Wiring
1.
Photocell 24V+ (Brown)
2.
Photocell Black (N/C)
3.
Photocell 24V - (Blue & White)
4.
Switch connection COM
5.
Switch Connection N/O
6.
LED light strip 24vdc +
7.
LED light strip 24vdc -
8.
Battery backup 24vdc +
9.
Battery backup 24vdc -
Programming Buttons / LED’s
LED 1 LED 2 LED 3
Photocell Brown 24V
Photocell Black N/C
Photocell Blue & White 24V-
Aerial
LED Light Strip max 14.4 watts
LED Light Strip max 14.4 watts
Switch connection COM
Switch connection N/O