Automatic Closing (default set to OFF)
1. Press P button for 5 seconds, LED’s 1, 2& 3 will illuminate.
2. Press + button twice, LED 1& 2 will flash to enter programming mode.
3. Press + or
-
button to select auto close time in accordance with the chart below.
4. Press P button to confirm auto close time.
LED Status Closing Time in Seconds
LED 1, 2 & 3 Flash
Not active
LED1 flashes once every 3 seconds
30 seconds
LED 1 Flashes twice every 3 seconds
60 seconds
LED 1 Flashes 3 times every 3 seconds
90 seconds
LED 1 Flashes 5 times every 3 seconds
120 seconds
LED 1 Flashes 6 times every 3 seconds
180 seconds
LED 1 Flashes 7 times every 3 seconds
210 seconds
LED 1 Flashes 8 times every 3 seconds
240 seconds
If auto time close is selected, before the door starts to close the courtesy light will flash for 20
seconds. When the door starts to close, the courtesy light remains on and remains on for 3
minutes.
Alarm Programming:
1. Press P button for 5 seconds, LED’s 1,2 & 3 illuminate
2. Press + button 3 times, LED 2 & 3 flash
3. Press + to check the status of the Alarm i.e on or off.
4. Press + or - to toggle between alarm on or alarm off.
LED
Display
Status Function
LED 1 Flashes once per 3 seconds
Alarm ON
LED 1 Flashes twice every 3 seconds
Alarm OFF
If the alarm is ON and auto time close function is OFF, the alarm will sound when the door
has been left in the fully open position for more than 10 minutes.
It will then beep for 30 seconds every 10 minutes until the door is closed.
Programming Auto Closing & Alarm
12
3
S
P
+
-
Programming LED’s