NRG Instructions
SRA System | All-Weather PVH Kit
SRA_All-Weather_PVH_Kit_Instructions
Rev. 5.0
support@nrgsystems.com | Page 19
18 April 2018
3.2 Connecting the VU01 & Pyranometer to the SRA Tower & SymphoniePRO
3.2.1 Attach the ventilator to the SRA Tower top plate
Mount the ventilator and pyranometer to the top plate of the NRG SRA tower using the appropriate
holes. Level the ventilator and pyranometer. See figure 3-1
Note: NRG SRA Tower top plates produced before September 2017 may not have the appropriate
holes to mount the VU01 ventilator. You can either measure and carefully drill the appropriate holes,
or contact NRG to purchase an updated top plate.
Figure 3-1: Mounted VU01 (with SR20) and a second SR20.
3.2.2 Connect the Hukseflux pyranometer to your SymphoniePRO data logger
The Hukseflux-supplied pyranometer cable has 8 wires. Not all wires are needed to connect to the
SymphoniePRO. Figure 3-2 below illustrates how to make this connection properly.
Figure 3-2