NRG USER MANUAL
SymphoniePLUS3 User Guide
SymphoniePLUS3_DataLogger_Manual
Rev. 17
support@nrgsystems.com | Page 123
31 December 2018
DATA RETRIEVER SOFTWARE: CHANGING IPACK AND SENSOR SETTINGS FROM A
REMOTE LOCATION BY CREATING A PATCH FILE
Cautions
Extreme care must be taken when patching ISP parameters. If you make a mistake (specifying the wrong
ISP phone number, for example), you risk cutting communication with the logger, and a site visit will be
required.
Creating the Patch File
A “patch” is a change to the iPack or logger configuration information. Patch files are generated by SDR
and manually sent to the iPack’s mailbox by the user. The iPackGPS event log will show
“PATCH_DOWNLOAD_EVT” and “PATCH_APPLY_EVT” to help track the installation of the patch.
Sensor Patch
If you need to add or change a sensor, go to the “Site Information Editor” window.
Select the sensor entry that you wish to change, make changes, and then select File>Save Site to save
changes (or create a new entry by following instructions in “Creating a New Site History Entry”).
Close the Site Editor window and go to Site>Create Sensor Patch. Select the site, and click “OK.”
In the “Create Patch File” window, enter the time and date at which the change occurred, and check the
boxes corresponding to the sensor channels affected by the change.