NRG USER MANUAL
SymphoniePLUS3 User Guide
SymphoniePLUS3_DataLogger_Manual
Rev. 17
support@nrgsystems.com | Page 34
31 December 2018
PRE-INSTALLATION SETUP: IPACK CONFIGURATION
Items required to configure (program) an iPack
You will need the following items to configure an iPack or iPackGPS. Be sure you have all of these items
before continuing:
Symphonie Data Retriever Software
Computer - system requirements are specified in the Symphonie Data Retriever Software and
Accessories section of this manual. You must follow the instructions to install the software
before proceeding.
iPack programming cable (available from NRG Systems)
USB to serial converter with driver (if your computer does not have a 9-pin serial port)
All ISP and phone account information (WindLinx subscribers will be provided this information
and an *.ipk file from the WindLinx web portal)
Configuration (Programming) recommendations
iPack configuration should always be done in the office before going to the field. Bringing an “active,
ready to go” iPack to the field will insure the installation can be performed as quickly as possible, saving
valuable field time and expense. Please note that if your logger revision is 8, 7, 11 or later, you have the
ability to program the iPack through the logger’s iPack Access Port. However, the iPack Access Port is
intended for field use. For pre-installation programming of iPacks in your office, we recommend using
the programming cable with PC as described below.
Grounding
Please take care to observe good grounding practices when configuring your iPack. If you are in a dry
office environment, make sure to discharge yourself before handling the iPack. The best solution is to
place the iPack on a grounded anti-static mat.
Connecting the iPack to the Computer
Connect the iPack using a standard 9-pin female to 25-pin male AT Modem cable to the serial port on
your PC. The 9-pin end goes to the PC, and the 25-pin end goes to the iPack. Connect the computer end
first, and then connect the iPack end. If your computer doesn’t have a 9-pin serial port, you will need to
use a USB to serial converter. Ensure that the proper drivers are installed for the converter cable.
Starting Symphonie Data Retriever iPack Configuration Software
Start the Symphonie Data Retriever Software from the Windows Start menu. The program is usually
found here: C:\NRG\SymDR\SDR.exe.