Thread the band clamps through the outer slots of the brackets on the back of the shelter box. Wrap the
band clamps around the tower and secure with a 5/16” hex nut driver. A drill with a driver attachment
will speed up the band clamp tightening process.
5.
Mounting on Lattice Towers
Thread the two band clamps (size 36) through the inner slots on the brackets on the back of the shelter
box. Wrap hose clamps around tower and tighten the band clamps with a 5/16” hex nut driver. A drill
with a driver attachment will speed up the band clamp tightening process.
6.
Attach the Logger/iPack/mounting plate Assembly to the Shelter Box
Mount the assembly into the shelter box into the four mounting screws by feeding the top holes onto
the top two screws, lining up the bottom notches with the bottom screws, then pushing the plate
downwards so that the four screws capture the corners of the mounting plate.
Secure by tightening the screws with a P2 screwdriver.