SymphoniePRO User Manual
Rev. 8
support@nrgsystems.com | Page 11
11 January 2018
Internal Flash memory stores up to 175 days of statistical data (no SD card installed). A 512 MB SD card
(sold separately) provides 10+ years of statistical data storage. A 2 GB SD card is available and should be
used if also storing 1 Hz sample data.
High-resolution analog-to-digital conversion
Convenient access to complete sensor history information in the Timeline screen
SymphoniePRO Desktop Application is included. The software is used to configure loggers and iPacks,
keep track of site data, and produce versatile tab-delimited text files (ASCII) compatible with leading
industry software. Additionally, the software allows the user to view real-time data and apply firmware
updates to loggers and iPacks. International numeric formats are supported.
Integrated Bing map and Google Earth
POPAuto software utility included with SymphoniePRO Desktop Application to automate extraction of
emailed data
Communications
iPackGPS kits for cellular (2G GSM, 3G GSM, CDMA, DoCoMo) communications provide remote data
collection via e-mail and/or MetLink (TCP/IP).
iPackACCESS kits for Ethernet and BGAN M2M satellite communications provide remote data collection
via Modbus as well as e-mail and/or MetLink.
Loggers with any Symphonie iPack kit allow remote changes to sensor configuration and communication
parameters via MetLink.
SymphoniePRO Desktop Application allows pre-installation programming of iPackGPS or iPackACCESS
and SymphoniePRO loggers through USB. The configuration file contains all the parameters for both the
iPack and the logger.
Communication and antenna signal test features allow on-site testing of iPack.
Firmware for the iPack (and SymphoniePRO logger) can be upgraded remotely or on site using
SymphoniePRO Desktop Application.
Integrated Global Positioning System (GPS) in iPackGPS and iPackACCESS
Channels
12 counter channels available for measuring wind speed or other pulsed frequency signals such as rain
gauges or other totalizer type sensors.
All counter inputs are universal and can accommodate NRG Class 1, NRG 40C, WindSensor P2546A-OPR
/P2546C-OPR, Thies First Class Advanced or other pulse output anemometers and do not require P-
SCMs. Channels 8 and 9 optimized for high frequency sine wave signals.
Provides 14 analog channels used for measuring wind direction or a range of other parameters including
temperature, barometric pressure, relative humidity and solar energy (7 channels are configurable with
P-SCM cards, while 7 channels are reserved for use with vanes, temperature probes, NRG BP20 & NRG
RH sensors).
Differential inputs available on P-SCM analog channels
Summary of Contents for SymphoniePRO
Page 1: ......
Page 74: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 74 11 January 2018 ...
Page 76: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 76 11 January 2018 ...
Page 77: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 77 11 January 2018 ...
Page 78: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 78 11 January 2018 ...
Page 134: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 134 11 January 2018 ...
Page 137: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 137 11 January 2018 ...
Page 139: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 139 11 January 2018 ...
Page 142: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 142 11 January 2018 ...